WINDOWS PROGRAMMING & MODEM SETUP
10-259
System 2 Installation / Programming Manual
CHAPTER 10
WINDOWS PROGRAMMING &
MODEM SETUP
Introduction
Getting Started
Determine which COM port you will be using for your connection to System 2. If you are unsure,
use Microsoft's Utility program MSD to assist you in determining which ports are available.
Making the Connection
All COM ports on PCS are either 9 pin or 25 pin male connectors. To make the connection from
the System 2 to the PC, you will need a 5 conductor 22 gauge cable with an overall shield.
If you’re using a 25 pin connection at the PC, follow the illustration in Figure 13.
Your connection should be:
9 Pin Connector (P1) - System 2 25 Pin Male Connector (PC Location)
Pin #2 - RXD Pin #2 - TXD
Pin #3 - TXD Pin #3 - RXD
Pin #5 - GND Pin #7 - GND
Pin #7 - RTS Pin #5 - CTS
Pin #8- CTS Pin #4 - RTS
If your using a 9 pin connection at the PC, your connection should be:
9 Pin Connector (P1) - System 2 9 Pin Connector (PC Location)
Pin #2 - RXD Pin #3 - TXD
Pin #3 - TXD Pin #2 - RXD
Pin #5 - GND Pin #5 - GND
Pin #7 - RTS Pin #8 - CTS
Pin #8- CTS Pin #7 - RTS
Select the baud rate on System 2
U Select Option 18 (Baud Rates).
U Enter the number that corresponds with the fastest baud rate possible.
U For hardwired connections 9600 is best, press 3, then # .