PC/VDT PROGRAMMING - OVERRIDE OUTPUTS
9-249
System 2 Installation / Programming Manual
Override Outputs (Option #14)
This option allows the user to manually set the state of either the Ports (door relays) or any of
the four general purpose outputs.
Ports
The VDT will display the instructions:
1=Ports,2=Outputs
0=Quit
Type[1]
If you choose Ports, you can now choose which of the available Units ports you wish to
activate.
Unit Number
The VDT will display the instructions:
0=Master
1=Slave #1
2=Slave #2, etc
Enter Unit # [0]
You can select from any of the available units you may have “networked” together on the
System.
Port Number
After making you selection for which unit to program, you may select which Port Relay you
wish to toggle On or Off. The VDT will display the instructions:
1=Port,2=Port 2
0=Quit
Port [0]
On / Off
Next, you will can either turn the Port Relay On or Off. The VDT will display the instructions:
1=On,2=Off
0=Quit
Enter State[1]
The VDT will take you back to the Ports/Outputs selection prompt.
1=Ports,2=Outputs
0=Quit
Type[1]
To Override Outputs press 2. To exit press 0. The unit will return On-Line.