System 2 Installation / Programming Manual
PREFACE
This document is a complete reference manual for the Corby System 2 Access Control unit, expansion modules,
hardware, and software which are manufactured, designed, or distributed by Corby Industries, Inc., USA. It is
assumed that the user of this manual is expert in the installation of high security devices and has
professional knowledge in electronics and security related installations.
Corby Industries, Inc. USA reserves the right to make changes without notice in the products described in this
manual in order to improve design or performance. Corby assumes no responsibility for stenographic and/or clerical
errors or the suitability or unsuitability of Corby products used in combination with any electrical, electronic, or
mechanical system or subsystem.
CORBY INDUSTRIES, INC.
Corby has been supplying security professionals with quality security products since 1972 when we first introduced
the concept of a digital key to the security industry. Up to that time, everyone used a round metal key which is now
almost extinct thanks to the hundreds of thousands of "Corby Keys" installed everywhere around the world.
For over 25 years we have been a major supplier to alarm dealers and locksmiths around the world. Users of
Corby products include the FBI, Secret Service, and Department of Defense. Corby has hundreds of authorized
distributor locations in the USA and 17 foreign countries.
At Corby, our customer is the most important person in our business. We constantly strive to serve our customers
with quality and service which is second to none. At Corby, we always try to be the best!
PROPRIETARY NOTICE
The hardware and software described in this manual are proprietary products developed, owned, and distributed by
Corby Industries, Inc., Allentown, Pennsylvania, USA. The software is furnished to the user only under a license
for use on a single Computer System and may not be copied or reproduced in accordance with the terms of the
license and copyright laws.
Copyright © 1998 by Corby Industries, Inc. All rights reserved. The reproduction or utilization of this work in any
form or by any electronic, mechanical, or other means, now known or hereafter invented, including xerography,
photocopying, and recording, and in any information storage and retrieval system is forbidden without the written
permission of the publisher.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his/her own expense.
Windows
®
is a registered trademark of Microsoft
Citizen
®
is a registered trademark of Citizen.
USRobotics
®
is a registered trademark of USRobotics
Version 5.1V REV F-H Printed: July, 1998
Part number: 2353 Printed in USA
Przeglądanie stron 0
1 2 3 4 5 6 ... 335 336

Podsumowanie treści

Strona 1

System 2 Installation / Programming ManualPREFACEThis document is a complete reference manual for the Corby System 2 Access Control unit, expansion mo

Strona 2

SYSTEM OVERVIEW1-4System 2 Installation / Programming ManualZone Inputs The System 2 can monitor a “normally closed” or “closed circuit” switch or ala

Strona 3 - SECTION PAGE

LCD PROGRAMMING - ADD/CHANGE KEYPAD CODES8-94System 2 Installation / Programming ManualEnter Keypad Code þþþþEnter Code [ _ _ _ _ _ _ _ _ _ ]Press Any

Strona 4

LCD PROGRAMMING - ADD/CHANGE KEYPAD CODES8-95System 2 Installation / Programming ManualAssign These Output(s) þþþþOutputs [ - - - - ]Option Not Activ

Strona 5

LCD PROGRAMMING - ADD/CHANGE KEYPAD CODES8-96System 2 Installation / Programming ManualUse 0 thru 8 þþþþDoor 01 Schedule [ _ 0 ]Use 0 thru 8 þþþþDoor

Strona 6

LCD PROGRAMMING - ADD/CHANGE KEYPAD CODES8-97System 2 Installation / Programming Manual1=Yes, 2=NoEnter Anti-Passback [ 2 ]0=Make User Permanent þþþþE

Strona 7

LCD PROGRAMMING - ADD/CHANGE CARDS8-98System 2 Installation / Programming ManualUsers Enrolled 0000 þþþþWant to Continue? [ 1 ] Use Up to 4 Digits þþþ

Strona 8 - RS232 Communications

LCD PROGRAMMING - ADD/CHANGE CARDS8-99System 2 Installation / Programming ManualEnter Door # þþþþPress Any Key00Enter Door (0=Done) [ _ _ ]01Enter Doo

Strona 9 - Request-To-Exit Inputs

LCD PROGRAMMING - ADD/CHANGE CARDS8-100System 2 Installation / Programming ManualError!! þþþþPress Any KeyEnter Number þþþþEnter Card [00000 _ _ _ _ _

Strona 10 - Time Keeping

LCD PROGRAMMING - ADD/CHANGE CARDS8-101System 2 Installation / Programming ManualAssign These Output(s) þþþþOutputs [ - - - - ]Option Not Active! þþþ

Strona 11 - Tamper Switch

LCD PROGRAMMING - ADD/CHANGE CARDS8-102System 2 Installation / Programming ManualUse 0 thru 8 þþþþDoor 01 Schedule [ _ 0 ]Use 0 thru 8 þþþþDoor 02 Sch

Strona 12 - SYSTEM OVERVIEW

LCD PROGRAMMING - ADD/CHANGE CARDS8-103System 2 Installation / Programming Manual1=Yes, 2=NoEnter Anti-Passback [ 2 ]0=Make User Permanent þþþþEnter T

Strona 13 - QUICKSTART

SYSTEM OVERVIEW1-5System 2 Installation / Programming ManualElectronic Serial Number ChipEach System has a unique Electronic Serial Number (ESN) conta

Strona 14 - Activate Premium Options

LCD PROGRAMMING - ADD/CHANGE CARDS8-104System 2 Installation / Programming ManualUsers Enrolled 0001 þþþþWant to Continue? [ 1 ]After you have success

Strona 15 - Keypad Test

LCD PROGRAMMING - ADD/CHANGE DATA CHIPS8-105System 2 Installation / Programming ManualUsers Enrolled 0000 þþþþWant to Continue? [ 1 ] Use Up to 4 Digi

Strona 16 - Card Reader Test

LCD PROGRAMMING - ADD/CHANGE DATA CHIPS8-106System 2 Installation / Programming ManualEnter Door # þþþþPress Any Key00Enter Door (0=Done) [ _ _ ]01 þþ

Strona 17 - Printer/VDT Test

LCD PROGRAMMING - ADD/CHANGE DATA CHIPS8-107System 2 Installation / Programming Manual01 03 þþþþEnter Door (0=Done) [ _ _ ]Error!! þþþþPress Any KeyT

Strona 18 - If Everything tests OK

LCD PROGRAMMING - ADD/CHANGE DATA CHIPS8-108System 2 Installation / Programming ManualEnter Number þþþþEnter ChipPress Any Key þþþþDuplicate Code!User

Strona 19 - Quick Installation

LCD PROGRAMMING - ADD/CHANGE DATA CHIPS8-109System 2 Installation / Programming ManualAssign These Output(s) þþþþOutputs [ - - - - ]Option Not Active

Strona 20

LCD PROGRAMMING - ADD/CHANGE DATA CHIPS8-110System 2 Installation / Programming ManualUse 0 thru 8 þþþþDoor 01 Schedule [ _ 0 ]Use 0 thru 8 þþþþDoor 0

Strona 21 - VERSIONS & UPGRADES

LCD PROGRAMMING - ADD/CHANGE DATA CHIPS8-111System 2 Installation / Programming Manual1=Yes, 2=NoEnter Anti-Passback [ 2 ]0=Make User Permanent þþþþEn

Strona 22

LCD PROGRAMMING - ADD/CHANGE DATA CHIPS8-112System 2 Installation / Programming ManualPress Any KeyBad Code!Users Enrolled 0001 þþþþWant to Continue?

Strona 23 - OPTIONAL EQUIPMENT

LCD PROGRAMMING - BATCH ENROLLING USERS8-113System 2 Installation / Programming ManualBatch Enroll Users (Option #9)Batch enrollment allows you to en

Strona 24 - Surge Protection Device

SYSTEM OVERVIEW1-6System 2 Installation / Programming Manual(Page intentionally left blank)

Strona 25

LCD PROGRAMMING - BATCH ENROLL KEYPAD CODES8-114System 2 Installation / Programming ManualUsers Enrolled 0000 þþþþWant to Continue? [ 1 ]Use Up to 4 D

Strona 26

LCD PROGRAMMING - BATCH ENROLL KEYPAD CODES8-115System 2 Installation / Programming ManualEnter Door # þþþþPress Any Key00Enter Door (0=Done) [ _ _ ]0

Strona 27 - INSTALLATION

LCD PROGRAMMING - BATCH ENROLL KEYPAD CODES8-116System 2 Installation / Programming Manual01 03 Enter Door (0=Done) [ _ _ ]Error!! þþþþPress Any KeyTh

Strona 28 - Earth Ground

LCD PROGRAMMING - BATCH ENROLL KEYPAD CODES8-117System 2 Installation / Programming ManualUse 4 DigitsEnter Seed # [ _ _ _ _ ]Assign These Output(s) þ

Strona 29 - Transformer and Battery

LCD PROGRAMMING - BATCH ENROLL KEYPAD CODES8-118System 2 Installation / Programming ManualOption Not Active! þþþþPress Any KeyNote: Although the displ

Strona 30

LCD PROGRAMMING - BATCH ENROLL KEYPAD CODES8-119System 2 Installation / Programming ManualUse 0 thru 8 þþþþDoor 01 Schedule [ _ 0 ]Use 0 thru 8 þþþþDo

Strona 31 - Wiring Surge Protection

LCD PROGRAMMING - BATCH ENROLL KEYPAD CODES8-120System 2 Installation / Programming Manual1=Yes, 2=NoEnter Anti-Passback [ 2 ]0=Make User Permanent þþ

Strona 32

LCD PROGRAMMING - BATCH ENROLL KEYPAD CODES8-121System 2 Installation / Programming ManualPlease Stand By . . .Use Up to 4 Digits þþþþFirst User # [ _

Strona 33 - Keypad Ground

LCD PROGRAMMING - BATCH ENROLL CARDS8-122System 2 Installation / Programming ManualUsers Enrolled 0000 þþþþWant to Continue? [ 1 ]Use Up to 4 Digits þ

Strona 34 - LED Connections:

LCD PROGRAMMING - BATCH ENROLL CARDS8-123System 2 Installation / Programming ManualUse Up to 4 Digits þþþþNumber of Users [ _ _ _ _ ]Enter Door # þþþþ

Strona 35 - Back To Back Readers

QUICKSTART2-7System 2 Installation / Programming ManualCHAPTER 2QUICKSTARTBench TestU Power up. Connect supplied transformer to Terminals #2 and #3.

Strona 36 - Anti-Passback with Readers

LCD PROGRAMMING - BATCH ENROLL CARDS8-124System 2 Installation / Programming Manual01 03 Enter Door (0=Done) [ _ _ ]Error!! þþþþPress Any KeyEnter Num

Strona 37 - Bar Code Readers

LCD PROGRAMMING - BATCH ENROLL CARDS8-125System 2 Installation / Programming ManualUse 4 DigitsEnter Seed # [ _ _ _ _ ]Assign These Output(s) þþþþOutp

Strona 38

LCD PROGRAMMING - BATCH ENROLL CARDS8-126System 2 Installation / Programming ManualOption Not Active! þþþþPress Any KeyNote: Although the display stat

Strona 39 - Data Chip Readers

LCD PROGRAMMING - BATCH ENROLL CARDS8-127System 2 Installation / Programming ManualUse 0 thru 8 þþþþDoor 01 Schedule [ _ 0 ]Use 0 thru 8 þþþþDoor 02 S

Strona 40 - Data Chip Reader Wire Runs

LCD PROGRAMMING - BATCH ENROLL CARDS8-128System 2 Installation / Programming Manual1=Yes, 2=NoEnter Anti-Passback [ 2 ]0=Make User Permanent þþþþEnter

Strona 41 - Magnetic Stripe Card Readers

LCD PROGRAMMING - BATCH ENROLL CARDS8-129System 2 Installation / Programming ManualPlease Stand By . . .Use Up to 4 Digits þþþþFirst User # [ _ _ _ _

Strona 42

LCD PROGRAMMING - BATCH ENROLL DATA CHIPS8-130System 2 Installation / Programming ManualUsers Enrolled 0000 þþþþWant to Continue? [ 1 ]Use Up to 4 Dig

Strona 43 - Proximity Readers

LCD PROGRAMMING - BATCH ENROLL DATA CHIPS8-131System 2 Installation / Programming ManualEnter Door # þþþþPress Any Key00Enter Door (0=Done) [ _ _ ]01E

Strona 44 - Proximity Reader Wire Runs

LCD PROGRAMMING - BATCH ENROLL DATA CHIPS8-132System 2 Installation / Programming Manual01 03 Enter Door (0=Done) [ _ _ ]Error!! þþþþPress Any KeyThe

Strona 45

LCD PROGRAMMING - BATCH ENROLL DATA CHIPS8-133System 2 Installation / Programming ManualUse 4 DigitsEnter Seed # [ _ _ _ _ ]Seed NumberIf you do not i

Strona 46 - Wiegand Readers

QUICKSTART2-8System 2 Installation / Programming ManualActivate Premium OptionsU If premium options have been purchased, each option must be activated

Strona 47

LCD PROGRAMMING - BATCH ENROLL DATA CHIPS8-134System 2 Installation / Programming ManualAssign These Output(s) þþþþOutputs [ - - - - ]Option Not Acti

Strona 48 - Door Locks

LCD PROGRAMMING - BATCH ENROLL DATA CHIPS8-135System 2 Installation / Programming ManualUse 0 thru 8 þþþþDoor 01 Schedule [ _ 0 ]Use 0 thru 8 þþþþDoor

Strona 49

LCD PROGRAMMING - BATCH ENROLL DATA CHIPS8-136System 2 Installation / Programming Manual1=Yes, 2=NoEnter Anti-Passback [ 2 ]0=Make User Permanent þþþþ

Strona 50 - Fail Safe Operation for RTE

LCD PROGRAMMING - BATCH ENROLL DATA CHIPS8-137System 2 Installation / Programming ManualEnter Number þþþþEnter ChipUse Up to 4 Digits þþþþFirst User #

Strona 51

LCD PROGRAMMING - DELETE USERS8-138System 2 Installation / Programming ManualUse 4 Digits þþþþ1st User [ _ _ _ _ ]Use 4 Digits þþþþLast User [ _ _ _ _

Strona 52 - Printer Connections

LCD PROGRAMMING - DELETE USERS8-139System 2 Installation / Programming Manual1=Yes, 2=No þþþþUser # 20Press Any KeyCode DeletedUse 4 Digits þþþþ1st Us

Strona 53 - Connecting To a VDT

LCD PROGRAMMING - REPORTS8-140System 2 Installation / Programming Manual1=Users þþþþSelect Report [ _ ]Reports (Option #11)In this option, you can li

Strona 54 - VDT Connections

LCD PROGRAMMING - REPORTS8-141System 2 Installation / Programming Manual1=Printer/VDT, 2=LCD þþþþPrinter/VDT or LCD [ 2 ]User#0001 KN#000012480Doors 1

Strona 55 - Short-Haul Modems

LCD PROGRAMMING - REPORTS8-142System 2 Installation / Programming ManualTo Start / Stop Print . . . þþþþWaiting . . .Press Any KeyWaiting . . .PRINTER

Strona 56 - Personal Computer (PC)

LCD PROGRAMMING - REPORTS8-143System 2 Installation / Programming Manual1=Door Perm þþþþChoose Report [ 0 ]To Start/Stop Print . . . þþþþWaiting . . .

Strona 57 - SYSTEM OPERATION

QUICKSTART2-9System 2 Installation / Programming ManualKeypad TestU Connect the keypad using a short cable. Connect up both ports for a two door Sys

Strona 58 - Status of AC Power

LCD PROGRAMMING - REPORTS8-144System 2 Installation / Programming ManualTo Start/Stop Print . . . þþþþWaiting . . .Press Any KeyWaiting . . .User Sche

Strona 59 - Time Schedules

LCD PROGRAMMING - REPORTS8-145System 2 Installation / Programming ManualTo Start/Stop Print . . . þþþþWaiting . . .Press Any KeyWaiting . . .User Code

Strona 60 - User Time Schedule Example

LCD PROGRAMMING - REPORTS8-146System 2 Installation / Programming ManualTo Start/Stop Print . . . þþþþWaiting . . .Press Any KeyWaiting . . .Temporary

Strona 61 - Automatic Door Operation

LCD PROGRAMMING - REPORTS8-147System 2 Installation / Programming Manual1=Yes, 2=NoDelete After Show? [ 2 ]1=Printer/VDT, 2=LCD þþþþPrinter/VDT or LCD

Strona 62 - Keypad and Reader Operation

LCD PROGRAMMING - REPORTS8-148System 2 Installation / Programming ManualTo Start / Stop Print . . . þþþþWaiting . . .Press Any KeyWaiting . . .To Star

Strona 63 - Network LEDs

LCD PROGRAMMING - REPORTS8-149System 2 Installation / Programming ManualTo Start / Stop Print . . . þþþþWaiting . . .ConfigurationThis option is not a

Strona 64

LCD PROGRAMMING - REPORTS8-150System 2 Installation / Programming ManualPress Any KeyWaiting . . .1=Printer/VDT, 2=LCD þþþþPrinter/VDT or LCD [ 2 ]Aft

Strona 65 - NETWORKING

LCD PROGRAMMING - REPORTS8-151System 2 Installation / Programming ManualUse 1 thru 8 þþþþSchedule to Show [ _ 0 ]Sched # 01 Cell # 0112345 - - 08:

Strona 66 - Network Setup

LCD PROGRAMMING - REPORTS8-152System 2 Installation / Programming ManualTo Start/Stop Print . . . þþþþWaiting . . .To Start/Stop Print . . . þþþþWaiti

Strona 67 - Buffer Size

LCD PROGRAMMING - SECRET # PASSWORD8-153System 2 Installation / Programming ManualUse 5 Digits þþþþCurrent Secret # [ _ _ _ _ _ ]0=QuitBad Secret#! [

Strona 68 - Programming Considerations

QUICKSTART2-10System 2 Installation / Programming ManualCard Reader TestU Connect the reader using a short cable. Connect up both ports for a two doo

Strona 69 - Trouble Shooting

LCD PROGRAMMING - INSTALL OPTIONS8-154System 2 Installation / Programming ManualElectronic Serial # is þþþþEnter Option [ _ _ _ _ ]Electronic Serial #

Strona 70 - Testing Additional Units

LCD PROGRAMMING - INSTALL OPTIONS8-155System 2 Installation / Programming ManualKey Error!Press Any KeyOption InstalledPress Any KeyEnter the Upgrade

Strona 71 - PROGRAMMING USING THE LCD

LCD PROGRAMMING - OVERRIDE OUTPUTS8-156System 2 Installation / Programming Manual1=Ports, 2=Outputs þþþþType [ 1 ]0=Master þþþþEnter Unit # [ 0 ]1=Por

Strona 72

LCD PROGRAMMING - OVERRIDE OUTPUTS8-157System 2 Installation / Programming Manual1=On, 2=Off þþþþEnter State [ 1 ]1=Ports, 2=Outputs þþþþType [ 1 ]On

Strona 73

LCD PROGRAMMING - OVERRIDE OUTPUTS8-158System 2 Installation / Programming Manual0=Master þþþþEnter Unit # [ 0 ]Use 1 thru 4 þþþþOutput [ 0 ]1=On, 2=O

Strona 74 - User Names

LCD PROGRAMMING - BAUD RATES8-159System 2 Installation / Programming Manual1=1200 þþþþBaud Rate [ 9600 ]Change BaudPress Any KeyBaud Rates (Option #1

Strona 75 - Memory Error

LCD PROGRAMMING - CLEAR USERS / CLEAR MEMORY8-160System 2 Installation / Programming Manual1=Yes, 2=NoAre You Sure? [ 2 ]1=Yes, 2=NoAre You Sure? [ 2

Strona 76

LCD PROGRAMMING - NETWORK OPTIONS8-161System 2 Installation / Programming ManualUnit in Standalone Mode þþþþEnter Net Option [ 0 ]Unit is a Master þþþ

Strona 77

LCD PROGRAMMING - NETWORK OPTIONS8-162System 2 Installation / Programming ManualEnter 1 thru 7Slave to Add [ 0 ]1=Yes, 2=No þþþþReload Slave? [ 2 ]Set

Strona 78

LCD PROGRAMMING - NETWORK OPTIONS8-163System 2 Installation / Programming ManualUnit in Standalone Mode þþþþEnter Net Option [ 0 ]RS485 TestIf you cho

Strona 79 - Enable DST? [ 2 ]

QUICKSTART2-11System 2 Installation / Programming ManualPrinter/VDT TestU If a printer, VDT, or PC available you can test them.U Printer test. Connec

Strona 80

LCD PROGRAMMING - BACKUP-RESTORE8-164System 2 Installation / Programming ManualBackup-Restore (Option #19)This option lets you backup all data to a di

Strona 81 - Time Schedule Example

LCD PROGRAMMING - BACKUP-RESTORE8-165System 2 Installation / Programming ManualRestore System 2This lets you restore all programmed information from a

Strona 82 - Choosing the Time Cell

LCD PROGRAMMING - BACKUP-RESTORE8-166System 2 Installation / Programming Manual(Page intentionally left blank)

Strona 83 - Holiday Date

PC/VDT PROGRAMMING9-167System 2 Installation / Programming ManualCHAPTER 9PROGRAMMING USING A VDT/PCIntroductionWhen in program mode, instructions and

Strona 84 - Trigger Time

PC/VDT PROGRAMMING - ACCESSING THE SYSTEM9-168System 2 Installation / Programming ManualAccessing the SystemMost users will never program the System,

Strona 85 - Trigger State

PC/VDT PROGRAMMING - POWER-UP MESSAGES9-169System 2 Installation / Programming ManualMEMORY ALLOCATION: You may choose any number to place in the [br

Strona 86

PC/VDT PROGRAMMING - POWER UP MESSAGES9-170System 2 Installation / Programming ManualRequired EventsWe recommend a history Storage Buffer of at least

Strona 87 - Select Option [ _ ]

PC/VDT PROGRAMMING - POWER-UP MESSAGES9-171System 2 Installation / Programming ManualNote: When you decide to utilize networking during the Initializa

Strona 88 - Selecting the Input Device(s)

PC/VDT PROGRAMMING - ENTERING PROGRAM MODE9-172System 2 Installation / Programming ManualEntering Program ModeWhile the System 2 is in run mode, the S

Strona 89 - Relay Type

PC/VDT PROGRAMMING - MAIN MENU9-173System 2 Installation / Programming ManualMain MenuEnter the various programming menu options from the list below.M

Strona 90 - Automatic Port Operation

QUICKSTART2-12System 2 Installation / Programming ManualIf There is a ProblemIf there is a problem with the board powering up, take the voltage measur

Strona 91 - Selecting Any Card/Chip Mode

PC/VDT PROGRAMMING - TIME AND DATE9-174System 2 Installation / Programming ManualTime and Date (Option #1)This option has two parts. You will be pro

Strona 92 - Output Mode

PC/VDT PROGRAMMING - DAYLIGHT SAVINGS TIME9-175System 2 Installation / Programming ManualDaylight Savings Time (Option #2)If the Daylight Savings Tim

Strona 93 - Trigger Event

PC/VDT PROGRAMMING - TIME SCHEDULES9-176System 2 Installation / Programming ManualProgramming Time Schedules (Option #3)Before we talk about programm

Strona 94

PC/VDT PROGRAMMING - TIME SCHEDULES9-177System 2 Installation / Programming ManualTime Schedule ExampleSuppose you want your clerical staff to have ac

Strona 95 - Automatic Output Operation

PC/VDT PROGRAMMING - TIME SCHEDULES9-178System 2 Installation / Programming ManualNow for a final note. What would this have looked like if, instead

Strona 96

PC/VDT PROGRAMMING - TIME SCHEDULES9-179System 2 Installation / Programming ManualDay-of-Week or Holiday DateNow that you've selected the time ce

Strona 97

PC/VDT PROGRAMMING - TIME SCHEDULES9-180System 2 Installation / Programming ManualChanging a CellIf you wish to change a “Holiday Cell” to a “Day of t

Strona 98

PC/VDT PROGRAMMING - TIME SCHEDULES9-181System 2 Installation / Programming ManualTrigger StateWe're almost there! By programming the DAY / HOLID

Strona 99

PC/VDT PROGRAMMING - SELECT CARD TYPE9-182System 2 Installation / Programming ManualSelect Card Type (Option #4)System 2 can accept five different re

Strona 100 - User Codes

PC/VDT PROGRAMMING - PORT CONFIGURATION9-183System 2 Installation / Programming ManualPort Configuration (Option #5)The System 2 has two Ports. Each

Strona 101 - Additional Outputs

QUICKSTART2-13System 2 Installation / Programming ManualQuick InstallationU Remove all power from the unit. AC and standby battery.U Run the wire. Y

Strona 102 - Door Schedules

PC/VDT PROGRAMMING - PORT CONFIGURATION9-184System 2 Installation / Programming ManualNote: Although the display states the Option is Not Active, the

Strona 103 - User Type

PC/VDT PROGRAMMING - PORT CONFIGURATION9-185System 2 Installation / Programming ManualSelecting the Input Device(s)Each System 2 Port can accept a Key

Strona 104 - Enrolling Cards

PC/VDT PROGRAMMING - PORT CONFIGURATION9-186System 2 Installation / Programming ManualRelay TypeWhen a valid code is entered, the Port’s door relay ma

Strona 105 - Door Number

PC/VDT PROGRAMMING - PORT CONFIGURATION9-187System 2 Installation / Programming ManualSelecting Any Card/Chip ModeIn this mode, any Corby Cards or Dat

Strona 106 - User Cards

PC/VDT PROGRAMMING - AUXILIARY OUTPUTS9-188System 2 Installation / Programming ManualProgram Aux Outputs (Option #6)A two-door System 2 provides four

Strona 107

PC/VDT PROGRAMMING - AUXILIARY OUTPUTS9-189System 2 Installation / Programming ManualTrigger EventAs we mentioned above, an output can be triggered by

Strona 108

PC/VDT PROGRAMMING - AUXILIARY OUTPUTS9-190System 2 Installation / Programming ManualAs discussed above, various system events can be assigned to oper

Strona 109 - Memory Full

PC/VDT PROGRAMMING - AUXILIARY OUTPUTS9-191System 2 Installation / Programming ManualNote: Although the display states the Option is Not Active, the o

Strona 110 - Want to Continue? [ 1 ]

PC/VDT PROGRAMMING - ANTI-PASSBACK9-192System 2 Installation / Programming ManualAnti-Passback (Option #7)You must have the Second Door option activa

Strona 111 - Enrolling Data Chips

PC/VDT PROGRAMMING - ADD/CHANGE KEYPAD CODES9-193System 2 Installation / Programming ManualAdd or Change User (Option #8)You must first Select Card T

Strona 112

System 2 Installation / Programming ManualNOTICEThe following features were not investigated by UL:- Keypads- Networking - Computer Interface- Data Ch

Strona 113

QUICKSTART2-14System 2 Installation / Programming Manual(Page intentionally left blank)

Strona 114 - Duplicate Code!

PC/VDT PROGRAMMING - ADD/CHANGE KEYPAD CODES9-194System 2 Installation / Programming ManualDoor NumberThis part may seem a bit confusing, so be sure t

Strona 115

PC/VDT PROGRAMMING - ADD/CHANGE KEYPAD CODES9-195System 2 Installation / Programming ManualThe VDT will display the instructions:01 03Enter Door (0=Do

Strona 116

PC/VDT PROGRAMMING - ADD/CHANGE KEYPAD CODES9-196System 2 Installation / Programming ManualNote: Although the display states the Option is Not Active,

Strona 117

PC/VDT PROGRAMMING - ADD/CHANGE KEYPAD CODES9-197System 2 Installation / Programming ManualDoor SchedulesAs we discussed in the schedule section of th

Strona 118 - Bad Code!

PC/VDT PROGRAMMING - ADD/CHANGE KEYPAD CODES9-198System 2 Installation / Programming ManualAnti-Passback(You may not be permitted to program Anti-Pass

Strona 119 - (Option #9)

PC/VDT PROGRAMMING - ADD/CHANGE CARDS9-199System 2 Installation / Programming ManualEnrolling CardsIn this option, you'll specify a user’s card,

Strona 120 - Batch Enrolling Keypad Codes

PC/VDT PROGRAMMING - ADD/CHANGE CARDS9-200System 2 Installation / Programming ManualDoor NumberThis part may seem a bit confusing, so be sure to read

Strona 121

PC/VDT PROGRAMMING - ADD/CHANGE CARDS9-201System 2 Installation / Programming ManualIf you select Port #3 and you do not have this System set-up for n

Strona 122

PC/VDT PROGRAMMING - ADD/CHANGE CARDS9-202System 2 Installation / Programming ManualNote: Although the display states the Option is Not Active, the ou

Strona 123 - Seed Number

PC/VDT PROGRAMMING - ADD/CHANGE CARDS9-203System 2 Installation / Programming ManualDoor SchedulesAs we discussed in the schedule section of this manu

Strona 124

VERSIONS & UPGRADES3-15System 2 Installation / Programming ManualCHAPTER 3VERSIONS & UPGRADESVersionsSystem 2 is available in two different ve

Strona 125

PC/VDT PROGRAMMING - ADD/CHANGE CARDS9-204System 2 Installation / Programming Manual Anti-Passback(You may not be permitted to program Anti-Passback).

Strona 126 - Code Type

PC/VDT PROGRAMMING - ADD/CHANGE DATA CHIPS9-205System 2 Installation / Programming ManualEnrolling Data ChipsIn this option, you'll specify a use

Strona 127

PC/VDT PROGRAMMING - ADD/CHANGE DATA CHIPS9-206System 2 Installation / Programming ManualDoor NumberThis part may seem a bit confusing, so be sure to

Strona 128 - User Number

PC/VDT PROGRAMMING - ADD/CHANGE DATA CHIPS9-207System 2 Installation / Programming ManualIf you select Port #3 and you do not have this System set-up

Strona 129 - Number of Users

PC/VDT PROGRAMMING - ADD/CHANGE DATA CHIPS9-208System 2 Installation / Programming ManualNote: Although the display states the Option is Not Active, t

Strona 130 - First Card Number

PC/VDT PROGRAMMING - ADD/CHANGE DATA CHIPS9-209System 2 Installation / Programming ManualDoor SchedulesAs we discussed in the schedule section of this

Strona 131

PC/VDT PROGRAMMING - ADD/CHANGE DATA CHIPS9-210System 2 Installation / Programming ManualUser Type(You may not be permitted to program User Type).This

Strona 132

PC/VDT PROGRAMMING - BATCH ENROLL USERS9-211System 2 Installation / Programming ManualBatch Enroll Users (Option #9)Batch enrollment allows you to ent

Strona 133

PC/VDT PROGRAMMING - BATCH ENROLL KEYPAD CODES9-212System 2 Installation / Programming ManualBatch Enrolling Keypad CodesSystem StatusWhen this Option

Strona 134

PC/VDT PROGRAMMING - BATCH ENROLL KEYPAD CODES9-213System 2 Installation / Programming ManualNumber of UsersHere you will specify the number of users

Strona 135

VERSIONS & UPGRADES3-16System 2 Installation / Programming Manual(Page intentionally left blank)

Strona 136 - Batch Enrolling Data Chips

PC/VDT PROGRAMMING - BATCH ENROLL KEYPAD CODES9-214System 2 Installation / Programming ManualThe VDT will display the instructions: 01 03Enter Door

Strona 137

PC/VDT PROGRAMMING - BATCH ENROLL KEYPAD CODES9-215System 2 Installation / Programming ManualNote: Although the display states the Option is Not Activ

Strona 138

PC/VDT PROGRAMMING - BATCH ENROLL KEYPAD CODES9-216System 2 Installation / Programming ManualDoor SchedulesAs we discussed in the schedule section of

Strona 139

PC/VDT PROGRAMMING - BATCH ENROLL KEYPAD CODES9-217System 2 Installation / Programming ManualAnti-Passback(You may not be permitted to program Anti-Pa

Strona 140

PC/VDT PROGRAMMING - BATCH ENROLL KEYPAD CODES9-218System 2 Installation / Programming ManualSystem Function While Batch LoadingIMPORTANT NOTE: The sy

Strona 141

PC/VDT PROGRAMMING - BATCH ENROLL CARDS9-219System 2 Installation / Programming ManualBatch Enrolling Wiegand, Proximity, Bar Code or Mag-Stripe Cards

Strona 142

PC/VDT PROGRAMMING - BATCH ENROLL CARDS9-220System 2 Installation / Programming ManualNumber of UsersHere you will specify the number of users you wan

Strona 143

PC/VDT PROGRAMMING - BATCH ENROLL CARDS9-221System 2 Installation / Programming ManualThe VDT will display the instructions: 01 03Enter Door (0=Done

Strona 144 - Delete Users (Option #10)

PC/VDT PROGRAMMING - BATCH ENROLL CARDS9-222System 2 Installation / Programming ManualSeed NumberNote: This prompt will only appear if any of your por

Strona 145 - Delete More?

PC/VDT PROGRAMMING - BATCH ENROLL CARDS9-223System 2 Installation / Programming ManualNote: Although the display states the Option is Not Active, the

Strona 146 - Reports (Option #11)

OPTIONAL EQUIPMENT4-17System 2 Installation / Programming ManualCHAPTER 4OPTIONAL EQUIPMENTProgramming WandTo assist you while entering Data Chips we

Strona 147 - Choosing the Output Device

PC/VDT PROGRAMMING - BATCH ENROLL CARDS9-224System 2 Installation / Programming ManualDoor SchedulesAs we discussed in the schedule section of this ma

Strona 148

PC/VDT PROGRAMMING - BATCH ENROLL CARDS9-225System 2 Installation / Programming ManualAnti-Passback(You may not be permitted to program Anti-Passback)

Strona 149 - User Door Permission

PC/VDT PROGRAMMING - BATCH ENROLL CARDS9-226System 2 Installation / Programming ManualSystem Function While Batch LoadingIMPORTANT NOTE: The system wi

Strona 150 - User Schedules

PC/VDT PROGRAMMING - BATCH ENROLL DATA CHIPS9-227System 2 Installation / Programming ManualBatch Enrolling Data ChipsSystem StatusWhen this Option is

Strona 151

PC/VDT PROGRAMMING - BATCH ENROLL DATA CHIPS9-228System 2 Installation / Programming ManualDoor NumberThis part may seem a bit confusing, so be sure t

Strona 152 - Temporary Users

PC/VDT PROGRAMMING - BATCH ENROLL DATA CHIPS9-229System 2 Installation / Programming ManualThe VDT will display the instructions:01 03Enter Door #To G

Strona 153 - Delete the Events?

PC/VDT PROGRAMMING - BATCH ENROLL DATA CHIPS9-230System 2 Installation / Programming ManualNote: Although the display states the Option is Not Active,

Strona 154

PC/VDT PROGRAMMING - BATCH ENROLL DATA CHIPS9-231System 2 Installation / Programming ManualDoor SchedulesAs we discussed in the schedule section of th

Strona 155 - Configuration

PC/VDT PROGRAMMING - BATCH ENROLL DATA CHIPS9-232System 2 Installation / Programming ManualAnti-Passback(You may not be permitted to program Anti-Pass

Strona 156 - Choosing Your Output Device

PC/VDT PROGRAMMING - BATCH ENROLL DATA CHIPS9-233System 2 Installation / Programming ManualSystem Function While Batch LoadingIMPORTANT NOTE: The syst

Strona 157

OPTIONAL EQUIPMENT4-18System 2 Installation / Programming ManualModemsModems can be used with a Video Display Terminal (VDT) or PC to call a System 2

Strona 158

PC/VDT PROGRAMMING - DELETE USERS9-234System 2 Installation / Programming ManualDelete Users (Option #10)This option removes a single user or a group

Strona 159 - Re-enter New Secret #

PC/VDT PROGRAMMING - DELETE USERS9-235System 2 Installation / Programming ManualThe VDT will count users it is deleting from the System.The VDT will d

Strona 160 - Install Options (Option #13)

PC/VDT PROGRAMMING - REPORTS9-236System 2 Installation / Programming ManualReports (Option #11)In this option, you can list Users, Events, Port Confi

Strona 161 - Enter the Upgrade Key

PC/VDT PROGRAMMING - REPORTS9-237System 2 Installation / Programming ManualChoosing the Output DeviceThe next choice you have is to view the users on

Strona 162 - Port Number

PC/VDT PROGRAMMING - REPORTS9-238System 2 Installation / Programming ManualNetwork ModeUsersBe sure to “List Users” using a printer after you have all

Strona 163 - On / Off

PC/VDT PROGRAMMING - REPORTS9-239System 2 Installation / Programming ManualUser SchedulesPress Any Key to Start the print process.To Start/Stop Print

Strona 164 - Output Number

PC/VDT PROGRAMMING - REPORTS9-240System 2 Installation / Programming ManualUser CodesPress Any Key to Start the print process.To Start/Stop Print ...P

Strona 165 - Baud Rates (Option #15)

PC/VDT PROGRAMMING - REPORTS9-241System 2 Installation / Programming ManualEventsSo far, we've talked about the System 2 taking a user code and g

Strona 166 - Clear Memory (Option #17)

PC/VDT PROGRAMMING - REPORTS9-242System 2 Installation / Programming ManualPRINTER/VDTIf using a Printer, VDT or PC to print / list users you may pres

Strona 167 - Network Options (Option #18)

PC/VDT PROGRAMMING - REPORTS9-243System 2 Installation / Programming ManualConfigurationThis option is not available if you are using an LCD. You mus

Strona 168 - Slave Unit

OPTIONAL EQUIPMENT4-19System 2 Installation / Programming ManualVideo Display Terminal / Personal ComputerSystem 2 has a built in, 9600 baud serial po

Strona 169 - RS485 Test

PC/VDT PROGRAMMING - REPORTS9-244System 2 Installation / Programming ManualCard Type = NonePort 01: Keypad Relay Time = 005 Schedule = 01Port 02: Keyp

Strona 170 - Backup-Restore (Option #19)

PC/VDT PROGRAMMING - REPORTS9-245System 2 Installation / Programming ManualPRINTER/VDTIf you selected 1=Printer/VDT as your output device the VDT will

Strona 171

PC/VDT PROGRAMMING - SECRET # PASSWORD9-246System 2 Installation / Programming ManualSecret # Password (Option #12)This is the options to change the

Strona 172

PC/VDT PROGRAMMING - INSTALL OPTIONS9-247System 2 Installation / Programming ManualInstall Options (Option #13)The System 2 has a number of “user ins

Strona 173 - PROGRAMMING USING A VDT/PC

PC/VDT PROGRAMMING - INSTALL OPTIONS9-248System 2 Installation / Programming ManualEnter the Upgrade KeyAfter contacting Corby, give us your Electroni

Strona 174 - Accessing the System

PC/VDT PROGRAMMING - OVERRIDE OUTPUTS9-249System 2 Installation / Programming ManualOverride Outputs (Option #14)This option allows the user to manua

Strona 175 - Power-up Messages

PC/VDT PROGRAMMING - OVERRIDE OUTPUTS9-250System 2 Installation / Programming ManualOverride OutputsIf you chose to Override Outputs, you can now choo

Strona 176

PC/VDT PROGRAMMING - BAUD RATES9-251System 2 Installation / Programming ManualBaud Rates (Option #15)This option allows the user to change the Baud R

Strona 177

PC/VDT PROGRAMMING CLEAR USERS/MEMORY9-252System 2 Installation / Programming ManualClear Users (Option #16)This option allows you to clear any progr

Strona 178 - Entering Program Mode

PC/VDT PROGRAMMING - NETWORK OPTIONS9-253System 2 Installation / Programming ManualNetwork Options (Option #18)When you first powered up the unit, (ba

Strona 179 - Main Menu

OPTIONAL EQUIPMENT4-20System 2 Installation / Programming Manual(Page intentionally left blank)

Strona 180 - Time and Date (Option #1)

PC/VDT PROGRAMMING - NETWORK OPTIONS9-254System 2 Installation / Programming ManualConfigure NetworkIf you choose to configure the network, the VDT wi

Strona 181 - Enable DST? [2]

PC/VDT PROGRAMMING - NETWORK OPTIONS9-255System 2 Installation / Programming ManualRS485 TestIf you chose the RS485 Test, the output will last for app

Strona 182

PC/VDT PROGRAMMING - BACKUP-RESTORE9-256System 2 Installation / Programming ManualBackup-Restore (Option #19)This option lets you backup all data to a

Strona 183

PC/VDT PROGRAMMING - BACKUP-RESTORE9-257System 2 Installation / Programming ManualRestore System 2This lets you restore all programmed information fro

Strona 184

PC/VDT PROGRAMMING - BACKUP-RESTORE9-258System 2 Installation / Programming Manual(Page intentionally left blank)

Strona 185

WINDOWS PROGRAMMING & MODEM SETUP10-259System 2 Installation / Programming ManualCHAPTER 10WINDOWS PROGRAMMING &MODEM SETUPIntroductionGetting

Strona 186

WINDOWS PROGRAMMING & MODEM SETUP10-260System 2 Installation / Programming ManualWindows 3.1Starting Windows from a DOS promptU Type C:\WINDOWS &l

Strona 187

WINDOWS PROGRAMMING & MODEM SETUP10-261System 2 Installation / Programming ManualWindows 95 (HyperTerminal Private Edition 3.0)Starting Windows fr

Strona 188 - Select Card Type (Option #4)

WINDOWS PROGRAMMING & MODEM SETUP10-262System 2 Installation / Programming ManualSet-up & Installation for the 4126 USRobotics ModemSoftware S

Strona 189

EPROM & RAM CHIPS11-263System 2 Installation / Programming ManualCHAPTER 11INSTALLING AN EPROM OR RAM1. Remove the external battery. (Unplug the

Strona 190

INSTALLATION5-21System 2 Installation / Programming ManualCHAPTER 5INSTALLATIONPLAN THE JOBUNDERSTAND THE EQUIPMENTREAD THE MANUALThis short section i

Strona 191

EPROM & RAM CHIPS11-264System 2 Installation / Programming Manual(Page intentionally left blank)

Strona 192

TROUBLESHOOTING12-265System 2 Installation / Programming ManualCHAPTER 12TROUBLESHOOTINGNothing on LCD/ no LEDs onPossible Cause:U Electrical Outlet -

Strona 193

TROUBLESHOOTING12-266System 2 Installation / Programming ManualDoor Ajar & Forced Entry messages appear without being wiredPossible Cause:U When t

Strona 194

TROUBLESHOOTING12-267System 2 Installation / Programming ManualMy proximity reader works, but doesn’t have the advertised read-rangePossible Cause: U

Strona 195

TROUBLESHOOTING12-268System 2 Installation / Programming Manual“Memory Corrupt” and “Reset” messages while programming theunitPossible Cause:U The sys

Strona 196

FAQ’S13-269System 2 Installation / Programming ManualCHAPTER 13FREQUENTLY ASKED QUESTIONSQ. Must I have an earth ground for the System 2?A. Yes. A go

Strona 197

FAQ’S13-270System 2 Installation / Programming ManualQ. Can I connect an on-site terminal and modem to the System 2 at the same time?A. No. There is o

Strona 198 - Anti-Passback (Option #7)

FAQ’S13-271System 2 Installation / Programming ManualQ. Can the System 2 use other manufacture’s Wiegand cards?A. We use customized 30-bit Wiegand car

Strona 199 - Enrolling Keypad Codes

FAQ’S13-272System 2 Installation / Programming Manual(Page intentionally left blank)

Strona 200

AVAILABLE USERS CHARTA-273System 2 Installation / Programming ManualAPPENDIX AAVAILABLE USERS CHARTSTEP 1. Select the appropriate base number of user

Strona 201

INSTALLATION5-22System 2 Installation / Programming ManualEarth GroundThis is very important because the System 2 must be protected from voltage trans

Strona 202

AVAILABLE USERS CHARTA-274System 2 Installation / Programming Manual(Page intentionally left blank)

Strona 203

LCD MESSAGESB-275System 2 Installation / Programming ManualAPPENDIX BLCD MESSAGESAC Off = AC power loss. AC On = AC power restored.AP Error = Ant

Strona 204

LCD MESSAGESB-276System 2 Installation / Programming ManualMem Clear = All memory was cleared.Module Reset = One of the small processors have rese

Strona 205

TERMINAL DESCRIPTIONSC-277System 2 Installation / Programming ManualAPPENDIX CTERMINAL DESCRIPTIONSTerminal #1 - Earth GroundThis terminal must be con

Strona 206

TERMINAL DESCRIPTIONSC-278System 2 Installation / Programming ManualTerminal #22 - (-) Common negativeThis is the System 2's common negative for

Strona 207

TERMINAL DESCRIPTIONSC-279System 2 Installation / Programming ManualTerminals #35 through #36 - Shunt ContactsThese contacts are rated at 5 AMPS 30 vo

Strona 208

TERMINAL DESCRIPTIONSC-280System 2 Installation / Programming Manual(Page intentionally left blank)

Strona 209

GLOSSARYD-281System 2 Installation / Programming ManualAPPENDIX DGLOSSARYABAAmerican Bankers Association. This association set a standard used in Mag

Strona 210

GLOSSARYD-282System 2 Installation / Programming ManualCPU Central Processing Unit. Usually the main microprocessor in the system.CTSClear to Send.

Strona 211

GLOSSARYD-283System 2 Installation / Programming ManualForced EntryA condition that exists when a door is forced open prior to a valid user entering t

Strona 212

INSTALLATION5-23System 2 Installation / Programming ManualTransformer and BatteryTransformerThe main power source for System 2 is a UL listed transfor

Strona 213

GLOSSARYD-284System 2 Installation / Programming ManualProximity A type of card technology that sends wireless digital data from a card to a reader th

Strona 214

GLOSSARYD-285System 2 Installation / Programming ManualUL Underwriters Laboratories. An organization that certifies the safety and functionality ofel

Strona 215

GLOSSARYD-286System 2 Installation / Programming Manual(Page intentionally left blank)

Strona 216

WIRING DIAGRAMSE-287System 2 Installation / Programming ManualAPPENDIX EWIRING DIAGRAMSFigure 1 Block Diagram ...

Strona 217

WIRING DIAGRAMSE-288System 2 Installation / Programming ManualCAUTION!!!If you use this System to operate a DC door strike, magnetic lock, relay, or a

Strona 220

Figure3-PCBDescriptionsandLayout48CHARACTERLIQUIDCRYSTALDISPLAYRELAY1 (+)5VDCAUX1OUTPUT1(+)6VDC(+)12VDCEMRDROPRELAYBATTERYRELAYRXD RELAY2TXDCTSAUX2DCD

Strona 221

Figure4-TerminalDescriptions1 2 3 4 5 6 7 8 9 10 11 12 13 14 1516.5VAC40VAAUXILIARYRELAYSARE5AMP,30VDC181920212223242526272829303132333435363718192021

Strona 222

Figure5-TestPoints18192021222324252627282930313233343536371819202122232425262728293031323334353637OPTIONALEQUIPMENTPLUG-INSH3THESELEDsSHOULDBEON:(+)5V

Strona 223

TABLE OF CONTENTSSECTION PAGESystem 2 Installation / Programming ManualCHAPTER 1 SYSTEM OVERVIEW ...

Strona 224

INSTALLATION5-24System 2 Installation / Programming ManualExternal Back-up Power If you are using an external 12 volt back-up power supply that has it

Strona 225

Figure6-ShieldandGroundingLayoutTYPICALGROUNDINGANDBONDINGLAYOUT.ALLGROUNDSANDBONDSMUSTCONFORMTONATIONALELECTRICALCODESTANDARDS.14GAUGEMINIMUMSystem2C

Strona 226

Figure7-WiringtheShieldtoEarthGround1 2 3 4 5 6 7 8 9 10 11 12 13 14 151819202122232425262728293031323334353637181920212223242526272829303132333435363

Strona 227

Figure8-BatteryandTransformer1 2 3 4 5 6 7 8 9 10 11 12 13 14 1516.5VAC40VAPLUGTHISTRANSFORMERINTOA120VOLTOUTLET.IFUSINGASURGEPROTECTOR,PLUGINTOSOCKET

Strona 228

Figure9-PrinterConnectionCORBYSERIALPRINTERSHIELDDONOTCONNECTATTHISENDWHITEBLACKGREENMALEDB25PINCONNECTORSOLDERSHIELDOFCABLETO9PINCONNECTORCASE3720DON

Strona 229 - Press Any Key

Figure10-Terminal&PrinterConnectionsSHIELDDONOTCONNECTATTHISENDWHITEREDBLUEGREENBLACKMALEDB25PINCONNECTORCONNECTTOMODEMPORTONBACKOFVDT325471 2 3 4

Strona 230

Figure11-TerminalUsingPhoneModemsSHIELDDONOTCONNECTATTHISENDVDTMODEMSWITCHSETTINGS MODEMSWITCHSETTINGSCORBYSERIALPRINTERANSIVIDEODISPLAYTERMINALTODIAL

Strona 231

REDWHITEGREENBLACKBLUE328720Figure12-TerminalUsingShort-HaulModems1 2 3 4 5 6 7 8 9 10 11 12 13 14 15SHIELDDONOTCONNECTATTHISENDFEMALEDB25CONNECTORFEM

Strona 232

Figure13-PC&PrinterConnections1 2 3 4 5 6 7 8 9 10 11 12 13 14 15FEMALEDB25PINCONNECTORCONNECTTOMODEMPORTONBACKOFPCOPTIONALLOCALPARALLELPRINTER(CE

Strona 233

Figure14-Keypadw/DoorAjar&RTEREDWIREOFGREENLEDYELLOWWIREOFGREENLEDSHIELDCONNECTSTOTHEGROUNDSCREWONTHEKEYPADCIRCUITBOARD1000FTMAXIMUMDISTANCEFROMSY

Strona 234

Figure15-BarCodeReaderw/DoorAjar&RTECLOSEDCIRCUITMAGCONTACTFORDOORAJAR,FORCEDENTRY,ANDTIMECANCELBLACKGREENWHITEORANGEYELLOWREDBROWNSHIELDBLUECONNE

Strona 235

INSTALLATION5-25System 2 Installation / Programming ManualWiring Surge ProtectionThe wire between the transformer and the System 2 should be two condu

Strona 236

Figure16-DataChipReaderw/DoorAjar&RTECLOSEDCIRCUITMAGCONTACTFORDOORAJAR,FORCEDENTRY,ANDTIMECANCELBLACKWHITEORANGEYELLOWBLUENOTUSEDBROWNGREENREDCON

Strona 237

Figure17-DataChipReaderw/DoorAjar&RTE(-)BLACKX2X1ORANGE(+)REDBLACKRTEBUTTONOPENCIRCUITCONTACTCLOSESWHENBUTTTONISPRESSED"A"GREENN.C.N.O.&

Strona 238

Figure18-KeriProximityReaderw/DoorAjar&RTECLOSEDCIRCUITMAGCONTACTFORDOORAJAR,FORCEDENTRY,ANDTIMECANCELBLACKGREENWHITEORANGEYELLOWREDBROWNSHIELDBLU

Strona 239

Figure19-OutdoorMag-StripeReaderw/DoorAjar&RTECLOSEDCIRCUITMAGCONTACTFORDOORAJAR,FORCEDENTRY,ANDTIMECANCELBLACKGREENWHITEORANGEYELLOWREDBROWNSHIEL

Strona 240

Figure20-ProximityCardReaderw/DoorAjar&RTECLOSEDCIRCUITMAGCONTACTFORDOORAJAR,FORCEDENTRY,ANDTIMECANCELBLACKGREENWHITEORANGEYELLOWBLUENOTUSED BROWN

Strona 241

Figure21-HIDMiniProxReaderw/DoorAjar&RTECLOSEDCIRCUITMAGCONTACTFORDOORAJAR,FORCEDENTRY,ANDTIMECANCELBLACKGREENWHITEORANGEYELLOWREDBROWNSHIELDBLUEC

Strona 242

Figure22-HIDProximityReaderw/DoorAjar&RTECLOSEDCIRCUITMAGCONTACTFORDOORAJAR,FORCEDENTRY,ANDTIMECANCELBLACKGREENWHITEORANGEYELLOWBLUENOTUSED BROWNS

Strona 243

CLOSEDCIRCUITMAGCONTACTFORDOORAJAR,FORCEDENTRY,ANDTIMECANCELBLACKGREENWHITEORANGEYELLOWBLUENOTUSED BROWNSHIELDREDCONNECTBLACKWIRESWITHAWIRENUTWIRENUTC

Strona 244

Figure24-WiegandCardReaderw/DoorAjar&RTECLOSEDCIRCUITMAGCONTACTFORDOORAJAR,FORCEDENTRY,ANDTIMECANCELBLACKGREENWHITEORANGEYELLOWREDBROWNSHIELDBLUEC

Strona 245

Figure25-DoorStrikeandDCPowerSupply1819202122232425262728293031323334353637INPUTINPUT(+)12VDC@1AMPMAX(-)NEGATIVE12VDCPOWERSUPPLYACTRANSFORMERA1N4001DI

Strona 246

INSTALLATION5-26System 2 Installation / Programming ManualKeypadsOverviewKeypads are designed to be flush or surface mounted on a wall about 60 inches

Strona 247 - PC/VDT PROGRAMMING - REPORTS

Figure26-MagneticLockandDCPowerSupply181920212223242526272829303132333435363712VDCMAGNETICDOORHOLDERA1N4001DIODEMUSTBEUSEDORTHESYSTEM2BOARDWILLBEDAMAG

Strona 248 - Door Closed 07:22:40 04/05/97

Figure27-DoorAjar&Request-To-ExitCLOSEDCIRCUITMAGCONTACTFORDOORAJAR,FORCEDENTRY,ORTIMECANCELBLACKORANGEYELLOWREDBROWNSHIELDBLUECONNECTBLACKWIRESWI

Strona 249 - Waiting

Figure28-FailSafeOperationforRequest-To-Exit2 3 4 51819202122232425262728293031323334353637112VDCMAGNETICDOORHOLDER1000FTMAXIMUMDISTANCEFROMSYSTEM2TOA

Strona 250

Figure29-ZoneInputusingaMagneticContactCLOSEDCIRCUITMAGCONTACTTOREPORTAZONEVIOLATION1819202122232425262728293031323334353637ZONEINPUTCOMMONNEGATIVE(-)

Strona 251

Figure30-LineExtenderModuleandWiegandCardReader2 3 4 51819202122232425262728293031323334353637WIEGAND-DATA0MAG-STRIPE-DATAWIEGAND-DATA1MAG-STRIPE-CLOC

Strona 252

Figure31-ShuntaClosedCircuitAlarmContactTOALARMPANELCLOSEDCIRCUITLOOPCLOSEDCIRCUITALARMCONTACTISSHUNTEDWHENTHEDOORISOPENEDBYAVALIDCODE1819202122232425

Strona 253

Figure32-EmergencyDropInput1 2 3 4 5 6 7 8 9 10 11 12 13 14 1512VDCOUTPUTFROMTHECONTROLPANEL22GAUGE500FTMAXIMUM

Strona 254

1Figure33-EPROMandRAMChipUpgrades62BELOWARETHELOCATIONSYOUWILLNEEDTOKNOWFOREPROMAND/ORRAMCHIPUPGRADES.FORDETAILEDINFORMATIONONTHEIRREPLACEMENTREFERTOT

Strona 255

Figure34-NetworkingMultipleSystemsTogether1)ThediagramaboveillustratestheMasterinthemiddleoftheRS485buss.ItisnotnecessarytoplacetheMasterinthemiddle,i

Strona 256

INDEXF-323System 2 Installation / Programming ManualINDEXAC PowerStatus ...6-52An

Strona 257

INSTALLATION5-27System 2 Installation / Programming ManualKeypad StylesChoose one of seven Corby Keypads.Indoor Keypads:4020 - flush mount, with one g

Strona 258

INDEXF-324System 2 Installation / Programming ManualBatch Enrolling Keypad Codes ... 8-114, 9-212Additio

Strona 259

INDEXF-325System 2 Installation / Programming ManualEnrolling DataChips ...8-105, 9-205Additiona

Strona 260

INDEXF-326System 2 Installation / Programming ManualMagnetic Stripe Card ReadersOverview ...

Strona 261

INDEXF-327System 2 Installation / Programming ManualPrinter ...4-18, 5-46Baud Rate

Strona 262

INDEXF-328System 2 Installation / Programming ManualReports ... 8-140, 9-236Configurat

Strona 263

INDEXF-329System 2 Installation / Programming ManualWiegand ReadersCards ...5-40O

Strona 264

INDEXF-330System 2 Installation / Programming Manual(Page intentionally left blank)

Strona 265 - MODEM SETUP

INSTALLATION5-28System 2 Installation / Programming ManualKeypad ConnectionsConnections from the wiring harness to the System 2 terminal strip:Yellow

Strona 266 - Windows 3.1

INSTALLATION5-29System 2 Installation / Programming ManualReadersOverview Readers are designed to be flush mounted or surface mounted on a wall depend

Strona 267

INSTALLATION5-30System 2 Installation / Programming ManualGrounding ReadersThe foil shield of the cable running to all Readers should only be connecte

Strona 268

INSTALLATION5-31System 2 Installation / Programming Manual Bar Code ReadersOverviewCorby Bar Code Readers will only work with Bar Code Cards that use

Strona 269 - INSTALLING AN EPROM OR RAM

INSTALLATION5-32System 2 Installation / Programming ManualBar Code Reader & LED ConnectionsAll wire connections are made from the wiring harness t

Strona 270 - EPROM & RAM CHIPS

INSTALLATION5-33System 2 Installation / Programming ManualData Chip ReadersOverviewData Chips contain an internal electronic memory chip which is bond

Strona 271 - TROUBLESHOOTING

TABLE OF CONTENTSSECTION PAGESystem 2 Installation / Programming ManualDoor Locks ...

Strona 272

INSTALLATION5-34System 2 Installation / Programming ManualData Chip Reader Wire RunsThese Readers require five wires with shield. Data Chip Readers a

Strona 273

INSTALLATION5-35System 2 Installation / Programming ManualMagnetic Stripe Card ReadersOverviewCorby Mag-Stripe Readers are available in indoor and out

Strona 274

INSTALLATION5-36System 2 Installation / Programming ManualMagnetic Stripe Reader & LED ConnectionsIndoor Magnetic Stripe Reader & LED Connecti

Strona 275 - FREQUENTLY ASKED QUESTIONS

INSTALLATION5-37System 2 Installation / Programming ManualProximity ReadersOverviewCorby Proximity Cards are read when they are brought within reading

Strona 276

INSTALLATION5-38System 2 Installation / Programming ManualMotorola/Indala Proximity Card Readers:4177 - Indoor/Outdoor Wiegand Style, black up to 4&qu

Strona 277

INSTALLATION5-39System 2 Installation / Programming ManualSo you can keep track of your color codes used in this installation, write in the color matc

Strona 278

INSTALLATION5-40System 2 Installation / Programming ManualWiegand ReadersOverviewAll wire connections are made using the screw terminal located on the

Strona 279 - AVAILABLE USERS CHART

INSTALLATION5-41System 2 Installation / Programming ManualWiegand Reader & LED Connections from the Reader to the System 2: ( Figure 24).GND to #2

Strona 280

INSTALLATION5-42System 2 Installation / Programming ManualDoor LocksDirect Current (DC) door strikes or DC magnetic door holding devices (mag locks) r

Strona 281 - LCD MESSAGES

INSTALLATION5-43System 2 Installation / Programming ManualDoor Ajar / Forced Entry / Time CancelDoor Ajar & Forced EntryDoor Ajar & Forced Ent

Strona 282

TABLE OF CONTENTSSECTION PAGESystem 2 Installation / Programming ManualBatch Enroll Users (Option #9) ...

Strona 283 - TERMINAL DESCRIPTIONS

INSTALLATION5-44System 2 Installation / Programming ManualYou must ensure that the RTE wire from Terminal #27 Never can be accessed byunauthorized per

Strona 284

INSTALLATION5-45System 2 Installation / Programming ManualHeavy-Duty RTE Button (p/n 4035) Use the following wire connections.Normal Operation:Green

Strona 285

INSTALLATION5-46System 2 Installation / Programming ManualPrinterCorby’s optional security printer (p/n 4007) is UL listed, requires 110/120VAC, 60hz

Strona 286

INSTALLATION5-47System 2 Installation / Programming ManualPrinter Baud Rate and Dip Switch SettingsThe System 2 outputs serial data at 9600 Baud with

Strona 287 - GLOSSARY

INSTALLATION5-48System 2 Installation / Programming ManualVideo Display Terminal (VDT) (p/n #4100)Unpack and inspect the terminal shipping box. Inclu

Strona 288

INSTALLATION5-49System 2 Installation / Programming ManualModems Phone ModemsDial-up telephone modems can be used for remote programming. One modem i

Strona 289

INSTALLATION5-50System 2 Installation / Programming ManualPersonal Computer (PC)Serial data is sent to and received from a PC via a RS232 data link wh

Strona 290

SYSTEM OPERATION6-51System 2 Installation / Programming ManualCHAPTER 6SYSTEM OPERATIONProgramming FunctionsProgramming is done through the Keypad and

Strona 291

SYSTEM OPERATION6-52System 2 Installation / Programming ManualDoor FunctionsTime CancelWhen the door is closed before the allotted time, any remaining

Strona 292

SYSTEM OPERATION6-53System 2 Installation / Programming ManualUser NumbersSystem 2 uses of two sets of numbers to organize its data. One is the user

Strona 293 - WIRING DIAGRAMS

TABLE OF CONTENTSSECTION PAGESystem 2 Installation / Programming ManualAPPENDIX A AVAILABLE USERS CHART ...

Strona 294 - CAUTION!!!

SYSTEM OPERATION6-54System 2 Installation / Programming ManualUser Time Schedule ExampleA time schedule granting access from 08:30 AM to 5:30 PM Monda

Strona 295

SYSTEM OPERATION6-55System 2 Installation / Programming ManualRelays & Time SchedulesAuto relay activation is a very powerful security management

Strona 296

SYSTEM OPERATION6-56System 2 Installation / Programming ManualSchedules that Cross MidnightIf a time schedule is required to cross the midnight hour,

Strona 297 - LIQUIDCRYSTALDISPLAY

SYSTEM OPERATION6-57System 2 Installation / Programming ManualUser LED OperationReader and Keypad LED outputs provide the user with feedback of System

Strona 298 - Figure4-TerminalDescriptions

SYSTEM OPERATION6-58System 2 Installation / Programming Manual(Page intentionally left blank)

Strona 299 - Figure5-TestPoints

NETWORKING7-59System 2 Installation / Programming ManualCHAPTER 7NETWORKINGIntroductionNetworking allows multiple System 2's to be linked togethe

Strona 300 - SHIELDEDCABLE

NETWORKING7-60System 2 Installation / Programming ManualRS485 WiringAttach the two wires from the RS485 line to Terminals #14 & #15. Be sure the

Strona 301

NETWORKING7-61System 2 Installation / Programming ManualBuffer SizeThe master and slave have adjustable event buffers to store system events. Example

Strona 302 - Figure8-BatteryandTransformer

NETWORKING7-62System 2 Installation / Programming ManualNetwork Speed and Processing TimeThe master polls a slave once a second so that it has time to

Strona 303 - Figure9-PrinterConnection

NETWORKING7-63System 2 Installation / Programming ManualTrouble ShootingIf you are experiencing problems with the RS485 buss, follow the sequence of t

Strona 304 - CONNECTOR

SYSTEM OVERVIEW1-1System 2 Installation / Programming ManualCHAPTER 1SYSTEM OVERVIEWIntroductionSystem 2 is a complete two-door Access Control System

Strona 305

NETWORKING7-64System 2 Installation / Programming ManualTesting Additional UnitsAdditional units can now be tested for transmission ability. Refer to

Strona 306

LCD PROGRAMMING INTRODUCTION8-65System 2 Installation / Programming ManualCHAPTER 8PROGRAMMING USING THE LCDIntroductionThe System 2 user interface ha

Strona 307

LCD PROGRAMMING INTRODUCTION8-66System 2 Installation / Programming ManualAccessing the SystemMost users will never program the System, but all users

Strona 308

LCD PROGRAMMING POWER-UP MESSAGES8-67System 2 Installation / Programming ManualWARNING ! ! ! þþþþClear Now? [ 1 ]Initializing . . . þþþþPower-up Messa

Strona 309 - SEEFAILSAFEDIAGRAM

LCD PROGRAMMING POWER-UP MESSAGES8-68System 2 Installation / Programming ManualEnter # of Rqrd EventsRequired Events [_100]Enter # of Temp UsersTempor

Strona 310

LCD PROGRAMMING POWER-UP MESSAGES8-69System 2 Installation / Programming Manual1=Yes, 2=NoAllow Networking? [ 2 ]Note: When you decide to utilize netw

Strona 311

LCD PROGRAMMING POWER-UP MESSAGES8-70System 2 Installation / Programming ManualElectronic Serial # is þþþþEnter Secret# - > [_ _ _ _ _]Electronic S

Strona 312 - KERIPROXIMITYREADER

LCD PROGRAMMING MAIN MENU8-71System 2 Installation / Programming ManualMain MenuEnter Selection [ _ 0 ]Main MenuEnter the various programming menu o

Strona 313

LCD PROGRAMMING - TIME & DATE8-72System 2 Installation / Programming ManualUse Military hh:mmEnter Time [00:00]Use mm/dd/yyEnter Date [01/01

Strona 314

LCD PROGRAMMING - DAYLIGHT SAVINGS TIME8-73System 2 Installation / Programming Manual1=Yes, 2=NoEnable DST? [ 2 ]Daylight Savings Time (Option #2)If

Strona 315

SYSTEM OVERVIEW1-2System 2 Installation / Programming ManualOutputs / InputsA two-door System is equipped with two of the following outputs/inputs: M

Strona 316

LCD PROGRAMMING - TIME SCHEDULES8-74System 2 Installation / Programming ManualProgramming Time Schedules (Option #3)Before we talk about programming

Strona 317

LCD PROGRAMMING - TIME SCHEDULES8-75System 2 Installation / Programming ManualTime Schedule ExampleSuppose you want your clerical staff to have access

Strona 318

LCD PROGRAMMING - TIME SCHEDULES8-76System 2 Installation / Programming ManualEnter Schedule # þþþþChoose Schedule [ _ 0 ]This Schedule = 01 þþþþChoos

Strona 319

LCD PROGRAMMING - TIME SCHEDULES8-77System 2 Installation / Programming ManualThis Schedule = 01 þþþþEnter Days [ - - - - - - - - ]This Schedule = 01

Strona 320

LCD PROGRAMMING - TIME SCHEDULES8-78System 2 Installation / Programming Manual1=Yes, 2=NoChange to Days? [ 2 ]This Schedule = 01 þþþþTrigger Time [ 00

Strona 321

LCD PROGRAMMING - TIME SCHEDULES8-79System 2 Installation / Programming ManualThis Schedule = 01 þþþþTrigger State [ 2 ]This Schedule = 01 þþþþTrigger

Strona 322

LCD PROGRAMMING - SELECT CARD TYPE8-80System 2 Installation / Programming Manual1=DataChip þþþþCard Type [ 0 ]Select Card Type (Option #4)System 2 ca

Strona 323 - 2CONDUCTOR22AWG

LCD PROGRAMMING - PORT CONFIGURATION8-81System 2 Installation / Programming Manual1=Program Ports þþþþSelect Option [ _ ]Port Configuration (Option #

Strona 324

LCD PROGRAMMING - PORT CONFIGURATION8-82System 2 Installation / Programming ManualUse 01 thru 16 þþþþEnter Port # [ 0 ]Option Not Active þþþþPress Any

Strona 325

LCD PROGRAMMING - PORT CONFIGURATION8-83System 2 Installation / Programming Manual1=Latching, 2=MomentaryRelay Type [ 2 ]Use 1 thru 255 SecondsMomenta

Strona 326 - Figure32-EmergencyDropInput

SYSTEM OVERVIEW1-3System 2 Installation / Programming ManualMain Relays Each System 2 has two independently controlled SPDT "C" form heavy d

Strona 327

LCD PROGRAMMING - PORT CONFIGURATION8-84System 2 Installation / Programming ManualUse 0 thru 8 þþþþPort Schedule [ _ 0 ]Automatic Port OperationAssign

Strona 328 - 22GAUGESHIELDEDTWISTEDPAIR

LCD PROGRAMMING - PORT CONFIGURATION8-85System 2 Installation / Programming ManualWARNING! þþþþPress Any Key1=ANY Card/Chip Mode þþþþSelect Mode [ 2 ]

Strona 329

LCD PROGRAMMING - AUXILIARY OUTPUTS8-86System 2 Installation / Programming ManualEnter Aux Output þþþþOutput [ 1 ]1=Latching, 2=MomentaryOutput Mode [

Strona 330

LCD PROGRAMMING - AUXILIARY OUTPUTS8-87System 2 Installation / Programming ManualEnter 1 thru 255 SecondsMomentary Time [ _ _ 2]1 = System Reset þþþþE

Strona 331

LCD PROGRAMMING - AUXILIARY OUTPUTS8-88System 2 Installation / Programming ManualAs discussed above, various system events can be assigned to operate

Strona 332

LCD PROGRAMMING - AUXILIARY OUTPUTS8-89System 2 Installation / Programming ManualUse 0 thru 8 þþþþPort Schedule [ _ 0 ]Option Not Active! þþþþPress An

Strona 333

LCD PROGRAMMING - ANTI-PASSBACK8-90System 2 Installation / Programming Manual1=Hard, 2=Soft þþþþEnter AP Type [ 1 ]Use Military hh:mmSet Forgive Time

Strona 334

LCD PROGRAMMING - ADD/CHANGE KEYPAD CODES8-91System 2 Installation / Programming ManualUsers Enrolled 0000 þþþþWant to Continue? [ 1 ] Add or Change U

Strona 335

LCD PROGRAMMING - ADD/CHANGE KEYPAD CODES8-92System 2 Installation / Programming ManualUse Up to 4 Digits þþþþEnter User [ _ _ _ 0 ]Enter Door # þþþþP

Strona 336

LCD PROGRAMMING - ADD/CHANGE KEYPAD CODES8-93System 2 Installation / Programming Manual01 03 þþþþEnter Door (0=Done) [ _ _ ]Error!! þþþþPress Any Key