Unit Numbers
OmniPro II systems have 511 total Unit Numbers. They consist of HLC, UPB, Z-Wave, CentraLite, RadioRA, ALC, Compose,
and X-10 module unit numbers, hardwire voltage output unit numbers, and internal flag unit numbers as follows:
OmniPro II
Unit Numbers
Module / Output Unit Numbers
1 - 16
HLC or Z-Wave Room 1 and 2, UPB Unit ID 1-16, Z-Wave Node ID 1-16, CentraLite loads 1-16,
RadioRA Lighting Zones or Master Controls 1-16, and X-10 modules 1 – 16 (House Code X)
17 - 32
HLC or Z-Wave Room 3 and 4, UPB Unit ID 17-32, Z-Wave Node ID 17-32, CentraLite loads 17-32,
RadioRA Lighting Zones and Master Controls 17-32, or X-10 modules 1 – 16 (House Code X+1)
(1 - 31)
ALC addresses 1-31, Module 1 - Branch 1 *
33 - 48
HLC or Z-Wave Room 5 and 6, UPB Unit ID 33-48, Z-Wave Node ID 33-48, CentraLite loads 33-48,
RadioRA Lighting Zones and Master Controls 33-48, or X-10 modules 1 – 16 (House Code X+2)
49 - 64
HLC or Z-Wave Room 7 and 8, UPB Unit ID 49-64, Z-Wave Node ID 49-64, CentraLite loads 49-64,
RadioRA Lighting Zones and Master Controls 49-64, or X-10 modules 1 – 16 (House Code X+3)
(33 - 63)
ALC addresses 1-31, Module 1 - Branch 2 *
65 - 80
HLC or Z-Wave Room 9 and 10, UPB Unit ID 65-80, Z-Wave Node ID 65-80, CentraLite loads 65-80,
or X-10 modules 1 – 16 (House Code X+4)
81 - 96
HLC or Z-Wave Room 11 and 12, UPB Unit ID 81-96, Z-Wave Node ID 81-96, CentraLite loads 81-96,
or X-10 modules 1 – 16 (House Code X+5)
(65 - 95)
ALC addresses 1-31, Module 1 - Branch 3 *
97 - 112
HLC or Z-Wave Room 13 and 14, UPB Unit ID 97-112, Z-Wave Node ID 97-112, CentraLite loads 97-112,
or X-10 modules 1 – 16 (House Code X+6)
113 - 128
HLC or Z-Wave Room 15 and 16, UPB Unit ID 113-128, Z-Wave Node ID 113-128,
CentraLite loads 113-128, or X-10 modules 1 – 16 (House Code X+7)
(97 - 127)
ALC addresses 1-31, Module 1 - Branch 4 *
129 - 144
HLC or Z-Wave Room 17 and 18, UPB Unit ID 129-144, Z-Wave Node ID 129-144,
CentraLite loads 129-144, or X-10 modules 1 – 16 (House Code X+8)
145 - 160
HLC or Z-Wave Room 19 and 20, UPB Unit ID 145-160, Z-Wave Node ID 145-160,
CentraLite loads 145-160, or X-10 modules 1 – 16 (House Code X+9)
(129 - 159)
ALC addresses 1-31, Module 2 - Branch 1 *
161 - 176
HLC or Z-Wave Room 21 and 22, UPB Unit ID 161-176, Z-Wave Node ID 161-176,
CentraLite loads 161-176, or X-10 modules 1 – 16 (House Code X+10)
177 - 192
HLC or Z-Wave Room 23 and 24, UPB Unit ID 177-192, Z-Wave Node ID 177-192,
CentraLite loads 177-192, or X-10 modules 1 – 16 (House Code X+11)
(161 - 191)
ALC addresses 1-31, Module 2 - Branch 2 *
193 - 208
HLC or Z-Wave Room 25 or 26, UPB Unit ID 193-208, Z-Wave Node ID 193-208, or
X-10 modules 1 – 16 (House Code X+12)
209 - 224
HLC or Z-Wave Room 27 and 28, UPB Unit ID 209-224, Z-Wave Node ID 209-224,
or X-10 modules 1 – 16 (House Code X+13)
(191 - 223)
ALC addresses 1-31, Module 2 - Branch 3 *
225 - 240
HLC Room 29 and 30, Z-Wave Room 29, UPB Unit ID 225-240, Z-Wave Node ID 225-232, or
X-10 modules 1 – 16 (House Code X+14)
241 - 256
HLC Room 31, UPB Unit ID 241-250, or X-10 modules 1 – 16 (House Code X+15)
(225 - 255)
ALC addresses 1-31, Module 2 - Branch 3 *
257 272
Outputs 1-16, 1st Expansion Enclosure *
273 288
Outputs 1-16, 2nd Expansion Enclosure *
289 304
Outputs 1-16, 3rd Expansion Enclosure *
305 320
Outputs 1-16, 4th Expansion Enclosure *
321 - 336
Outputs 1-16, 5th Expansion Enclosure *
337 352
Outputs 1-16, 6th Expansion Enclosure *
353 - 368
Outputs 1-16, 7th Expansion Enclosure *
369 - 384
Outputs 1-16, 8th Expansion Enclosure *
385 - 392
Voltage Outputs (1-8), Fully Configurable
393511
Internal Flags
“X” Represents the House Code setting on the OmniPro II Controller
“*” If used
WEB VERSION