Przeglądanie stron 0
Control & Security System
Owner’s Manual
Includes the SIA CP-01 Control Panel Standard
Features for False Alarm Reduction
WEB VERSION
Przeglądanie stron 0
1 2 3 4 5 6 ... 123 124

Podsumowanie treści

Strona 1 - WEB VERSION

Control & Security SystemOwner’s ManualIncludes the SIA CP-01 Control Panel Standard Features for False Alarm ReductionWEB VERSION

Strona 2

Page 1 INTRODUCTION Thank you for purchasing your new OmniPro II automation system. You are about to enjoy a new feeling of security, comfort, con

Strona 3

Page 91 CANADIAN INDUSTRY CANADA NOTICE Notice: The Industry Canada label identifies certified equipment. This certification means t

Strona 4

Page 92 APPENDIX A - DIAL OUT PLANNER Use the following dial-out planner to help you set-up the voice dial-out numbers: OmniPro II Voice Dial-O

Strona 5

Page 93 INSTRUCTIONS TO CALLED PARTY Dear ___________________________________________________________________ I have programmed my OmniPro II Hom

Strona 6

Page 94 APPENDIX B - TEXT DESCRIPTION CHARACTER CODES CODE CHAR CODE CHAR CODE CHAR CODE CHAR 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15

Strona 7

Page 95 APPENDIX C - VOICE DESCRIPTION CODES CODE DESCRIPTION 255 (ADDRESS MSG) 58 (BEEP) 254 (MEMO MESSAGE) 29 (PAUSE) 30 (SHORT PAUSE) 26 A. M.

Strona 8

Page 96 CODE DESCRIPTION 341 FALL 80 FAMILY 81 FAN 342 FATHER’S 343 FAULT 344 FEBRUARY 217 FENCE 5 FIFTEEN 17 FIFTY 218 FILE 345 FILTER 82 FIRE 219

Strona 9

Page 97 CODE DESCRIPTION 444 ONLINE 445 ONLY 233 OPEN 446 OPTION 131 OR 447 OTHER 448 OUT 132 OUTDOOR 133 OUTLET 449 OUTSIDE 450 OVER 234 OVERFLOW

Strona 10

Page 98 CODE DESCRIPTION 250 VAULT 536 VCR 537 VIDEO 538 VISITOR 539 VOLUME 540 WAITING 541 WALK 542 WALKWAY 251 WAREHOUSE 543 WARNING 187 WATER 54

Strona 11

Page 99 APPENDIX D – FIRMWARE UPDATES Description The OmniPro II Version 3.2 firmware adds the following new features: • Support for Clipsal C-B

Strona 12

C-Bus group address 0 is not supported. C-Bus lighting groups can be turned on, turned off, brightened, dimmed, set to a specific level, or toggled

Strona 13

Page 2 OVERALL DESCRIPTION Console Operation The console is designed with everything that is necessary for you to program and operate your OmniPro

Strona 14

About Lutron HomeWorks Lutron RadioRA uses a network of low voltage wires to communicate with and control HomeWorks lighting device

Strona 15

Programming for Lutron HomeWorks Units Note: To take advantage of the controlling HomeWorks devices via OmniPro II programming, programs must be w

Strona 16

User Settings User Settings consist of numbers, levels, times, dates, days of the week, durations, temperature settings, and humidity settings that

Strona 17

Program Blocks In previous version of the controller firmware, each automation program was constructed of a single line that consi

Strona 18

d. Thermostats: current temperature, heat setpoint, cool setpoint, heater currently running, air conditioning currently running, system

Strona 19

Vacation Hold In Vacation Hold mode, the thermostat ignores program schedule and remote system temperature setting changes for the duration of your

Strona 20

Energy Status When OmniPro II sends the time and date to the Omnistat2, it also sends the current Energy Level. When the Ener

Strona 21

LEVITON Access Control LEVITON Access Control allows you to access doors by opening an electric or magnetic lock, arm and disarm

Strona 22

Note: When a valid card or key tag is presented at the reader, all 9 LED indicators will illuminate and remain illuminated until the “Door Unlock” t

Strona 23

Method A) Typing in the ID Number of the Access Control Card or Key Tag: a. Enter the last 8 digits of the Access Control Card or Key Tag and the

Strona 24

Page 3 6- UP ARROW The Up Arrow key is used to scroll through menus and lists. The Up Arrow is used to scroll back through a list (for example, if

Strona 25

Each Access Control Card or Key Tag can be assigned to 1 or more Access Control Readers. When an Access Control Card or Key Tag is assigned to spec

Strona 26

WEB VERSION

Strona 27

WEB VERSION

Strona 28

WEB VERSION

Strona 29

LEVITON LIMITED WARRANTYLeviton warrants to the original consumer purchaser and not for the benefit of anyone else that products manuf

Strona 30

Page 4 When using the arrow keys to scroll through lists of areas, buttons, codes, temperature zones, units, or zones, only the name

Strona 31

Page 5 To silence “Trouble Beeps”, press the ' * ' key. For more information, see Trouble Indications. Confirmation Beep When you have s

Strona 32

Page 6 SECURITY SYSTEM OPERATION Disarming the Security System and Silencing Alarms Before going any further, you should know how to disarm your

Strona 33

Page 7 2 = NIGHT The NIGHT mode is used when you are asleep and everyone in your household is at home. In the Night mode, you

Strona 34

Page 8 What Happens When You Arm the Security System To arm the system into one of the 6 security modes, from the security menu, choose the security

Strona 35

Page 9 Bypassing Zones 8 = BYPASS You can Bypass a zone that you do not want protected while the system is armed. Bypassing is also the only way t

Strona 36

Page 10 What To Do When You Come Home If you enter your home while the system is armed in the Day, Night Delay, Away, or Vacation mode using an entr

Strona 37

WEB VERSION

Strona 38

Page 11 Fire Alarm Activated When the fire alarm is activated by the smoke/fire detector(s), the alarm responds exactly as described

Strona 39

Page 12 Police Emergency When the 1 key and the 3 key is pressed simultaneously, the Police Emergency alarm is activated. This alarm operates exact

Strona 40

Page 13 Trouble Indications The OmniPro II constantly monitors the alarm zones and several internal matters and will alert you if i

Strona 41

Page 14 Manager Code The Manager codes can arm/disarm the security system in assigned areas, during assigned times. The Manager code can access fun

Strona 42

Page 15 If the ' 0 ' (ALL) key had been selected, the display will show: DISARM ALL AREAS ENTER CODE: #=AREA As the fou

Strona 43

Page 16 Testing Your System LEVITON recommends testing your system on a weekly basis to ensure that you are fully protected. 1. Notify your Cent

Strona 44

Page 17 CONTROL Control Commands The control features of the OmniPro II make it easy and convenient to control almost any light or appliance from t

Strona 45

Page 18 When set to UPB, the OmniPro II controller can:  Send commands (on, off, bright, dim and level) to individual switches and modules  Rece

Strona 46

Page 19 When “Status Tracking” is enabled (this is the default setting), OmniPro II keeps track of the exact status of each unit even when a lighting

Strona 47

Page 20 The first unit number in each room (i.e. 1, 9, 17, 25, etc.) is reserved for controlling the room. The name for this unit should ref

Strona 48

WARNINGS AND CAUTIONS• Read and understand all instructions. Follow all warnings and instructions marked on the product.• Do

Strona 49

Page 21 About ALC ALC is intended for installation in homes, which have been pre-wired for installation of ALC system products. O

Strona 50

Page 22 Unit Numbers OmniPro II systems have 511 total Unit Numbers. They consist of HLC, UPB, Z-Wave, CentraLite, RadioRA, ALC, Compose, and X-10

Strona 51

Page 23 Scrolling Through Names The OmniPro II stores names for Units, Zones, Buttons, Codes, Temperatures, and Messages so that you don't hav

Strona 52

Page 24 Each lighting scene can also be set or easily changed using the pushbuttons on the LEVITON UPB™ 6-Button Room Controller, as follows: Step Op

Strona 53

Page 25  Press 0 (OFF) to turn the selected room off (all lighting loads in the room are turned off).  Press 1 (ON) to turn the selected room on

Strona 54

Page 26 Controlling RadioRA Units Entry Lights 0=OFF 1=ON 2=DIM 3=BRT ↓ Entry Lights 4=LVL 5=RMP 9=TIM #=STA↑  Press 0 (OFF) to turn the

Strona 55

Page 27 Ramp Command (ALC) When ALC Switch Modules are being used, it is possible to ramp the lighting level of an ALC Dimmer Switch to a new level

Strona 56

Page 28 Timed Commands The timed commands allow a units to be turned on or off for a specified period of time. The unit may be turned On fo

Strona 57

Page 29 Controlling Outputs The OmniPro II has eight outputs that can be used to switch relays. Outputs 1-8 are controlled as Unit Numbers 385-392,

Strona 58

Page 30 Leviton Scene Control OmniPro II supports Leviton Scene Control (a feature found in certain Leviton Switches). There are 256 Scenes that ca

Strona 59

Contents INTRODUCTION ...

Strona 60

Page 31 Scene Off Command Once the Scenes have been sent, press the 0 (OFF) key to command the four units in that Scene to turn off. Notes: 1. W

Strona 61

Page 32 Executing Phantom Buttons OmniPro II can turn on and turn off each of the 17 possible Phantom Buttons. Phantom Buttons must be pre-programm

Strona 62

Page 33 Buttons A powerful feature of the OmniPro II is the ability to program Buttons. A Button (also known as macro) is a number on

Strona 63

Page 34 LEVITON RC-Series Thermostats The following control actions are allowed for LEVITON Communicating Thermostats: • Set heating setpoints •

Strona 64

Page 35 The fan control on a thermostat may be switched between on and auto by selecting 4 (FAN) from the temperature menu: Upstairs FAN

Strona 65

Page 36 Cool temperature - the air temperature will be allowed to rise to this temperature when the energy saver is on. The following control action

Strona 66

Page 37 Downstairs 0=OFF 1=ON 2=HEAT ↓ Downstairs 3=COOL 9=TIME #=STAT ↑ ENTER TIME MINUTES (1-99) #=H

Strona 67

Page 38 When a temperature sensor is selected from the list of temperature devices, you may set a “Low” and “High” setpoint for a

Strona 68

Page 39 Status The Status function is used to display the status of various items in the system. To enter the status menu, fro

Strona 69

Page 40 1=CTRL 2=ZONE 3=SUN ↓ Press 1 (CTRL) to view the current status of each unit and to configure the HLC device that

Strona 70

Testing Your System ...

Strona 71

Page 41 2 = ZONE The Zone Status menu allows you to view and scroll through the status of each zone input. To enter the Zone menu, from the Stat

Strona 72

Page 42 The next series of displays shows the current analog reading for each security zone input. The displays show the readings for zones 1-

Strona 73

Page 43 Event Log The Event Log records the 250 most recent significant security system Events (happenings) and trouble conditions in the system. W

Strona 74

Page 44 Messages The Message menu is used to play and record the memo message and to quickly clear all text messages. The memo message is an eight-

Strona 75

Page 45 Show Message The 1 (SHOW) key allows you to display the selected text message(s) on the console's top-level display. This can be a

Strona 76

Page 46 Send Message (Pro-Link) The 6 (SEND) key allows you to send any of the text messages through the Pro-Link serial port. Y

Strona 77

Page 47 TELEPHONE CONTROL Telephone Interface Your OmniPro II is equipped with a built-in telephone response feature that allows you to control and

Strona 78

Page 48 Phone Access Denied - Remote Lockout The OmniPro II has a remote lockout feature to discourage youngsters (and adults who act that way) fro

Strona 79

Page 49 1 - Control Press 1 from the MAIN MENU to get to the CONTROL menu. If voice descriptions have been programmed, after a three-second

Strona 80

Page 50 Press the temperature zone you wish to control, then press #. Press the ' 0 ' key to select all LEVITON Thermostats. This is a si

Strona 81

Programmable Energy Saver Modules (PESMs) ...

Strona 82

Page 51 8 - Message This command allows you to record and verify the voice memo message, allows you to record and play custom mes

Strona 83

Page 52 To play one of the custom phrases, press the 6 key. " PLAY PHRASE: ENTER PHRASE NUMBER, THEN POUND." Press the phrase number (1

Strona 84

Page 53 Emergency Dial-Out Emergency dial out consists of two distinct parts: the "digital dialer" and the "voice dialer". Dig

Strona 85

Page 54 What You Hear - If Your OmniPro II Calls You When you pick up the phone and say something, the OmniPro II will say one of the following, dep

Strona 86

Page 55 Built-In Ethernet Port The built-in Ethernet port (J6) allows a device to connect to the OmniPro II controller via a network (i.e. Ethernet,

Strona 87

Page 56 192.168.0.101192.168.0.50192.168.0.51HAI OmniPro IIControllerHub orRouterComputerComputer Local Network Dynamic DNS If the controll

Strona 88

Page 57 Local / Wide Area Network To connect to an OmniPro II controller on a local network using LEVITON PC Access, under Configur

Strona 89

Page 58 SETUP Configuration and Advanced Control Programming (ACP) The Setup menu is used to configure operating parameters, program your

Strona 90

Page 59 Access Areas After an authority level has been entered, you will be prompted for access areas for the user. Specify which area(s) (if part

Strona 91

Page 60 If Daylight Savings Time is currently being observed (between spring and fall), set this item to "Yes". If Daylight Savings Time i

Strona 92

Voice Dialer ...

Strona 93

Page 61 1 = Add Programs The 1 (ADD) key is used to add new automation programs to the system. When you press the 1 (ADD) key, the Edit Program men

Strona 94

Page 62 The first program is displayed once the down arrow is pressed. The top line displays the time or button/event that activates the program and

Strona 95

Page 63 Edit Programs When Selecting the 1 (WHEN) key, from the Edit Program menu, allows the time or button/event that activates t

Strona 96

Page 64 Button and Event Programs Selecting 2 (BUTTON), from the "Edit When" menu, sets up a program to be activated when a macro button i

Strona 97

Page 65 Corresponding Switch Table Switch OmniPro II UPB 6-Button Keypad UPB 8-Button Keypad RadioRA Master Control ALC 4-Button StarLite Keypad 1

Strona 98

Page 66 AREA: ENTER AREA 0=ALL ↓ The area number should be entered followed by the ' # ' key, or the arrow keys may b

Strona 99

Page 67 Alarm Event Buttons Pressing the 5 (ALARM) key allows you to specify an event button activated upon the occurrence of an

Strona 100

Page 68 The arrow keys are used to select from a list of event buttons: • WHEN ENERGY LO • WHEN ENERGY MID • WHEN ENERGY HI • WHEN ENERGY CRIT

Strona 101

Page 69 Edit Program Command Selecting 2 (CMD), from the Edit Program menu, allows the commanded action for the program to be specified. The

Strona 102

Page 70 Unit Toggle Command Using LEVITON PC Access Software, you can create programs to toggle any unit (1-511) from its current state to the oppos

Strona 103

Edit Program Condition ...

Strona 104

Page 71 Program Button Commands Select the 3 (BUTTON) key to program a macro button. Specify the macro button to be executed - See Button Programs

Strona 105

Page 72 Program Message Commands Select the 8 (MESSAGE) key to show, log, clear, say, phone, or send a message. Specify the desired command - See M

Strona 106

Page 73 Edit Program Condition Selecting the 3 (&COND) key, from the Edit Program menu, allows the condition for the program to be specified. T

Strona 107

Page 74 The zone will be displayed and you will be prompted for the state of the zone: IF Front Door: 0=SECURE 1=NOT RDY Program Tim

Strona 108

Page 75 Set Up Dial The Set Up Dial menu is used to configure all of the telephone related items for the OmniPro II. To enter the Set Up Dial menu,

Strona 109

Page 76 Dial Out Number 1 Dial Out Number 1 is one of the 8 numbers that are stored in the system. In the event of an alarm, these numbers are dial

Strona 110

Page 77 Set Up Arming To configure different arming and disarming options, from the Setup menu, press the 5 (ARM) key. Entry Delay The Entry Delay

Strona 111

Page 78 Entry/Exit Chime When Entry/Exit Chime is set to Yes, the console(s) will beep once when a door on an entry/exit zone is opened, even if the

Strona 112

Page 79 Set up Miscellaneous To configure Miscellaneous items in the system, from the Set Up menu, press the 6 (MISC) key. High Security Mode In H

Strona 113

Page 80 House Codes 1-16 Format House Codes 1-16 can be configured to use the Standard (Preset Dim Command), Extended Code (Level Command), Lightoli

Strona 114

UNDERWRITER'S LABORATORIES REQUIREMENTS ... 89 FIRE ESCAPE PLANNING ...

Strona 115

Page 81 Time Clocks There are three Time Clocks in the system are used to conditionalize programs. They are used solely to define time periods duri

Strona 116

Page 82 It is not necessary to alter the time zone to compensate for daylight savings time, the OmniPro II will automatically adjust i

Strona 117

Page 83 Controller IP Address The controller’s local network IP address is used to identify the OmniPro II controller on the network. To view and a

Strona 118

Page 84 Set Up Names The system can be set up to display descriptive names such as "FRONT DOOR", "JOHN'S BEDROOM", or "

Strona 119

Page 85 Set Up Address The final setup item is accomplished over the telephone. This is the address that the system says when it

Strona 120

Page 86 AUDIO CONTROL Once configured by your installer, from any OmniTouch touchscreen, you can control on/off, volume, muting, transports, Audio S

Strona 121

Page 87 Unit numbers 473-508 are allocated for the Audio Zone names. These names should match the names of each Audio Zone in your audio distributio

Strona 122

Page 88 Table 1 - Audio Commands Code LEVITON Hi-Fi Russound 1 NuVo 2 NuVo Grand Concerto Xantech 3 Speakercraft 4 1 Power Power Power Power Powe

Strona 123

Page 89 UNDERWRITER'S LABORATORIES REQUIREMENTS For a complete list of requirements and restrictions when installing the OmniPro I

Strona 124

Page 90 FEDERAL COMMUNICATION COMMISSION NOTICE: 1. This equipment complies with Part 68 of FCC Rules. On the door, inside of the