LC75813E, 75813T
No.7159-2/26
Specifications
Absolute Maximum Ratings at Ta = 25C, V
SS
= 0V
Parameter Symbol Conditions Ratings unit
Maximum supply voltage
V
DD
max V
DD
–0.3 to +7.0
V
V
LCD
max V
LCD
–0.3 to +7.0
Input voltage
V
IN
1 CE, CL, DI,
INH
–0.3 to +7.0
V
V
IN
2 OSC –0.3 to V
DD
+0.3
V
IN
3 V
LCD
1, V
LCD
2 –0.3 to V
LCD
+0.3
Output voltage
V
OUT
1 OSC –0.3 to V
DD
+0.3
V
V
OUT
2 S1 to S87, COM1 to COM4, P1 to P8 –0.3 to V
LCD
+0.3
Output current
I
OUT
1 S1 to S87 300 A
I
OUT
2 COM1 to COM4 3 mA
I
OUT
3 P1 to P8 5mA
Allowable power dissipation Pd max Ta = 85°C 200 mW
Operating temperature Topr –40 to +85 C
Storage temperature Tstg –55 to +125 C
Allowable Operating Ranges at Ta = 40 to +85C, V
SS
= 0V
Parameter Symbol Conditions
Ratings
Unit
min typ max
Supply voltage
V
DD
V
DD
2.7 6.0
V
V
LCD
V
LCD
2.7 6.0
Input voltage
V
LCD
1 V
LCD
1
2/3V
LCD
V
LCD
V
V
LCD
2 V
LCD
2
1/3V
LCD
V
LCD
Input high-level voltage V
IH
CE, CL, DI,
INH
0.8V
DD
6.0 V
Input low-level voltage V
IL
CE, CL, DI,
INH
0 0.2V
DD
V
Recommended external
resistance
R
OSC
OSC
39 k
Recommended external
capacitance
C
OSC
OSC
1000 pF
Guaranteed oscillation range f
OSC
OSC
19 38 76 kHz
Data setup time tds CL, DI : Figure 2
160 ns
Data hold time tdh CL, DI : Figure 2
160 ns
CE wait time tcp CE, CL : Figure 2
160 ns
CE setup time tcs CE, CL : Figure 2
160 ns
CE hold time tch CE, CL : Figure 2
160 ns
High-level clock pulse width
tH CL : Figure 2
160 ns
Low-level clock pulse width
tL CL : Figure 2
160 ns
Rise time tr CE, CL, DI : Figure 2
160 ns
Fall time tf CE, CL, DI : Figure 2
160 ns
INH
switching time tc
INH
, CE : Figure 3
10 s
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality should not be assumed,