7 - FIRE ZONES
are used for devices such as smoke
detectors (4 wire), heat sensor, water flow, etc. that
need to be active 24 hours.
8 - DAY CIRCUIT
is used for devices such as window
foil, screens, etc. In a disarmed state, an activation
creates a trouble (trbl) condition and will report a
trouble code if programmed. In an armed state, an
activation will create an alarm condition.
ARMING MODE ENTRY/EXIT 1
and 2
PERIMETER
INSTANT
INTERIOR #1 INTERIOR #2 INTERIOR #3
AWAY Delayed Exit
Delayed Entry
Delayed Exit
Instant
Delayed Exit
Follower or
Instant
Delayed Exit
Follower or
Instant
Delayed
STAY Delayed Exit
Delayed Entry
Delayed Exit
Instant
Delayed Exit
Follower or
Instant
Bypassed Delayed
INSTANT Instant Always Instant Always Instant Always Bypassed Delayed
LOOP TYPE
is the second digit entry. The loop type
and value entered are:
0 - Normally Open
1 - Normally Closed
* 2 - Normally Open - Normally Closed
* 3 - N.O. - supervised w/EOL - reports trouble on
break, alarm on short
* 4 - N.C. - supervised w/EOL - reports trouble on
short, alarm on open
NOTE:
EOL resistor 2.2k ohm 1/2 watt
(Optex Part Number: 1401-4649).
ITEM A - Loop Response
- Adjusted in two digit
increments in a multiplier of 50 ms. A longer loop
response may be required for devices such as water
flow detectors. A shorter loop response may be
required for devices such as glass break detectors.
Value: 00 - 99 x 50 ms.,
Default: 05 (250 ms.)
.
ITEM B - Alarm Code
- (2 Digit Entry)
The panel will transmit this code when the zone
creates an alarm condition.
Value: 01 - FF,
Default: 00 (Disabled
).
ITEM C - Trouble Code
- (2 Digit Entry)
This code that will be transmitted when a zone that is
programmed for a Loop Type three or four creates a
trouble condition.
Value: 01 - FF,
Default: 00 (Disabled)
.
ITEM D - Bypass Code
- (2 Digit Entry)
This code will be transmitted when the zone is
bypassed and the system is armed if the zone is
programmed for bypass allowed (see Item G)
Value: 01 - FF,
Default: 00 (Disabled).
NOTE
:
BYPASS SHOULD NOT BE ALLOWED
ON FIRE CIRCUITS.
ITEM E - Restore Code
(2 Digit Entry)
This restore code is a common function that is
transmitted either after an alarm condition or after a
trouble (trbl) condition if programmed as loop type
three or four.
Value: 01 - FF,
Default: 00 (Disabled)
.
ITEM F -Zone Features
(MultipleEntries) Depressing
the number that corresponds to the option that you
wish to enable and it will also be displayed on the
LCD. Depressing a number that previously was
displayed will remove the number from the LCD and
disable the option.
(
Shows Default condition
)
OPTIONS
1 = Telephone Output
2 = Audible
3 = Pulse Bell
4 = PGM 1
5 = PGM 2
6 = Walk Test
7 = Monitor
8 = Silent Day - Audible Armed
1 - TELEPHONE OUTPUT
- is required to be enabled to
transmit all zone reporting codes. If the codes are
programmed and this function is not active, the zone report
codes will not transmit.
Default: YES
2 - AUDIBLE
- must be enabled to energize the steady bell
voltage output If this function is not enabled the zone will
be silent. (See Item 58 for cutoff times.)
Default: YES
Note:
For Temporal Pattern Set Audible to Yes
3 - PULSE BELL
- is required to be enabled to energize
the pulsing bell voltage output. Audible must also be
enabled to energize this function.
Default: NO
Note:
For Temporal Pattern Set Pulse Bell to Yes
4 - PGM OUTPUT 1
- is an open collector that sinks to
ground for the amount of time that is programmed under