False alarm reduction features
1. Delay before dial
This function enables the subscriber to abort the alarm
transmission of burglary zones. If the control panel is
disarmed within this prescribed time value.
Memory location: 53B
Value: 00 - 99 seconds
Default: 00 seconds
2. Open restore code
This report code will be transmitted when system is disarmed
after an alarm(s) has occurred during the armed period.
This function can be utilized as a cancel code with the central
station. The end user must be trained as to how this function
operates.
Memory location: 71B
Value: 00-FF
Default: 00 Disabled
3. Last 15 second pulsed beep of exit delay
This function informs the end user that the Exit time will expire
in 15 seconds, when arming in away mode.
4. Bell test
By enabling this feature, the bell will ring for 3 seconds when
system is armed. This function will alert anyone left on
premises that the system is armed.
Memory location: 76
Default: Disable
5. Zones set-up time on power up
On power up, G-824 ALPHA will ignore all zones for 3
seconds.
6. PGM output for armed status
PGM’s can be programmed to show armed status for
partitioned or non-partitioned status.
7. Zone shunt feature
This option allows you to auto bypass swinger zone in armed
condition.
8. Alarm verification on 2-wire smoke
This option will require two consecutive trip in a 60 second
period with smoke power reset in between to report 2-wire
smoke alarm.
9. Duress code
Separate duress code for all users (option).
10. 2-digit keypad zones
2 keys to be pressed simultaneously to detect keypad zones
such as panic, emergency & fire.
11. Call waiting disable
Phone number can be programmed to eliminate call waiting.
UNDERWRITERS LABORATORIES
COMPLIANCE VERIFICATION
When programming the Genesys 824, the following programs must be maintained to meet minimum UL requirements for Household
Burglar Systems, and/or commercial burglar alarm systems, and police connect.
Approved Bells
Amseco & Wheelock 12 volt motor bells.
Approved Smoke Detectors
Detection Systems DS250/DS250TH-Detector identifier=A
System sensor 2400/2400TH-Detector identifier=A
Sentrol 429C/429CT-Detector indentifier=510A
System sensor-2300T-Detector identifier=A
Exit Time not to exceed 60 seconds.
Entrance Time not to exceed 45 seconds including pre-alarm delay.
Loop Response not to exceed 1 second.
Bell and/or Siren - 4 minutes minimum (to meet UL residential Burg and Fire)
Bell and/or Siren - 15 minutes minimum (to meet UL commercial Burglar Alarm and Police Connect)
For Bell to Ring in Temporal Pattern the following settings must be entered:
Zone Type
programmed to
Fire 24 Hour
Audible
programmed to
Yes
Pulse Bell
programmed to
Yes
Burglar Alarm Loops must alarm in an Open or Shorted condition.
Low Battery must be programmed to report.
Two (2) separate telephone numbers must be programmed (Receiver 1 and Receiver 2)
Close Ringback - Program "YES".
Abnormal self test code must be programmed.
SMOKE DETECTORS
To reset Smoke Detector, enter four digit PIN.